6.3 Electrical connection

Pay attention to the rating plate data.
The mains connecting cable must at least
correspond to the type H 05 VV-F G 0,75.
After installation, plug the connecting cable plug
in an accessible socket. If the plug can no longer
be removed after installation, isolation of all poles
from the mains must be ensured by means of an
accessible isolator with a contact spacing of at least
3 mm.
VL 051-107
/01
AC 220-240V / 50Hz
FD xxxx
xxxxxx
max 260W
xxxxxxxx

6.4 Installation next to a gas hob

Pay attention to the following notes if you
wish to install a gas range next to the hob
ventilator.
– A locking bolt must be installed in the hob
ventilator to prevent the boom from swivelling
over the gas range.
– Extend the unit.
– Position the swivel arm in the centre.
– Open the flap on the rear.
– Fit a pin (accessory) in the collar of the acces-
sible mounting ring (black plastic part). Fit the
pin on the side opposite to the one where the
boom is no longer to swivel.
– Close the flap.
When operated next to gas appliances, the swivel
arm must be extended at least to the top edge of
the pan as otherwise the flame of the gas burner
will be impaired.