  • Page 1 Operating and assembly instructions VL 430/431 Hob ventilator...
  • Page 3: Table Of Contents

    VL 430 VL 431 Important notes Page For your safety Page 3 Operating for the first time Page 4 Maintenance Page 4 Features Page Features Page 5 Special accessories Page 5 Operation Page Cleaning and care Page Assembly instructions Page...
  • Page 4 The chapter entitled “Cleaning and Care" gives tips on how to keep your appliance looking good. And now we wish you lots of fun with your new hob ventilator. VL 430...
  • Page 5: For Your Safety

    If you have installed a gas appliance between the Do not operate the appliance without a grease filter. hob extractors VL 430/431, the gas hob has to be Only operate the appliance under supervision. The fitted with two air baffles LS 330 on the side of the appliance is intended solely for use in the hob while cooking.
  • Page 6: Operating For The First Time

    Remove the packaging from the appliance and appliance still does not work, please contact your dispose of it properly. Pay attention to the fact that dealer or your local Gaggenau customer service there are accessories in the packaging! agency. Specify the appliance type. The serial Keep packaging elements (e.g.
  • Page 7: Features

    2. Features Features 1 Ventilation flaps 2 Metal grease filter 3 Membrane key pad (VL 431 only) 4 Clamping screw 5 Suction extraction connection Special accessories AL 400-000 Edge trim RV 050-150 Bifurcated pipe for joining 2 x DN 125 into DN 150 LS 330-000 Air baffle...
  • Page 8: Operation

    3. Operation Note: VL 430 can only be operated in combination with VL 431. All operator inputs apply to both hob ventilators. That is to say: if you press the key for level 1, both hob ventilators are operated at level 1.
  • Page 9: Cleaning And Care

    4. Cleaning and care grease filters must be cleaned on a regular basis (at the latest after 30 hours of operation). Overgreased filters are a fire risk! Cleaning the grease filter • Switch appliance to level 1. The flaps open. •...
  • Page 10: Assembly Instructions

    5. Assembly instructions Important notes on installation Safe operation is possible whenever the partial vacuum in the place where the firing equipment The appliance must only be connected by is installed does not exceed 4 Pa (0.04 mbar). authorised specialist. The specialist is This can be achieved whenever the air needed for responsible for perfect functioning of the appliance combustion is able to enter through openings that...
  • Page 11: Installing The Appliance

    If you have installed a gas appliance between the hob extractors VL 430/431, the gas hob has to be fitted with two air baffles LS 330 on 5 1 0 the side of the hob while cooking.
  • Page 12 • Turn the clamping screws to the side. Insert the appliance with the control panel on the front into the cut-out and align it. Note: do not stick the appliance onto the worktop with silicone. • Turn the clamping screws under the countertop and tighten them evenly.
  • Page 13: Electrical Connection

    Electrical connection Pay attention to the rating plate data. Connectors VL 431 Observe the connecting scheme when connecting the hob ventilator and the fan module. connecting connecting cable cable to GB to VL 430 9000029649 en 12.04 EB...