G eneral information

K
C hecking the wall
G e n e r a l i n f o r m a t i o n
The wall must be level, vertical and adequately load-
bearing.
The depth of the bore holes must be the same
length as the screws. The wall plugs must have a
secure grip.
The enclosed screws and wall plugs are suitable for
solid brickwork. Suitable fasteners must be used
for other structures (e.g. plasterboard, porous
concrete, poroton bricks).
The maximum weight of the extractor hood is 40 kg.

Electrical connection

m
Warning – Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do not
kink or pinch the connecting cable during installation.
The required connection information can be found on
the rating plate on the top of the appliance.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
m
Warning – Risk of electric shock!
It must always be possible to disconnect the appliance
from the power supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed. If the plug can no longer be reached
after installation, an energy-isolating device in the
phases must be provided in the permanent electrical
installation in accordance with the installation
regulations. The permanent electrical installation must
only be wired by a professional electrician. We
recommend installing a residual-current circuit breaker
(RCCB) in the appliance's power supply circuit.

I nstallation

5
P reparing for installation
I n s t a l l a t i o n
Caution!
Ensure that there are no electrical wires, gas pipes or
water pipes in the area where holes are to be drilled.
If the extractor hood is to be operated in air extraction
mode, a flue duct must be fitted.
If the extractor hood is to be operated in air
recirculation mode, the activated charcoal filters
provided must be fitted.The flue duct does not need to
be fitted for air recirculation mode.
1
Determine where the extractor hood should be
positioned and lightly mark where the lower edge of
the appliance should be on the wall. Determine
where the middle should be based on the hob.
Note: We recommend fitting the extractor hood
such that the lower edge of the glass screen is in
line with the lower edges of the adjacent wall-hung
cabinets. Make sure that the specified safety
clearances from the hob are complied with.
2
Place the template against the line drawn on the
wall and fasten it in place. Mark where the screws
should be inserted.
To fit the flue duct, the template must be cut along
the marked cut line.