Safety Information For The Installer - Electrolux EBSL80A User Manual

Table of Contents

Advertisement

Information for appliances with metal
fronts:
Due to the appliance's cool front, when
the door is opened during or shortly after

Safety Information for the installer

• The set-up of the electrical installation is
arranged so that the appliance can be iso-
lated from the mains with a minimum 3 mm
all-pole contact separation.
Suitable isolation devices include, for ex-
ample, circuit breakers, fuses (screw type
fuses are to be removed from the holder),
RCDs and contactors.
• Anti-shock protection must be provided by
the installation.
• The built-in unit must meet the stability re-
quirements of DIN 68930.
• Built-in cookers and cooking surfaces are
equipped with special attachment sys-
Installation
1
200 cm²
590
550 min.
30
560 min.
20
530 min.
baking or roasting, there may be con-
densation of the inner glass panel for a
short while.
tems. For safety reasons, they must only
be combined with appliances from the
same manufacturer.
The use of heat protection strips is prohibited
for cookers and ovens with Pyrolytic Clean-
ing, if the recess has a rear wall and closed
ground-level compartment.
However installation is possible with a
ground-level compartment that has been
shortened by at least 20 mm and which has
base ventilation of the same cross-section.
541
546
10
584
567
21
electrolux 31
594
10
594

Advertisement