Advertisement

Quick Links

Hanover
READ AND SAVE THESE INSTRUCTIONS!
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper
installation; therefore, before attempting to install and operate your Casablanca fan, read this owner's manual completely and
carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at the circuit breaker or fuse box
before attempting any installation procedure.
INTRODUCTION
Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safe Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Sloped Ceiling Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Crossbar Mounting Bracket Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Lag Screw Installation (Optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Canopy Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Blade Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fan Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Hanging the Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Canopy Electrical Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Canopy Hatch Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Switch Housing Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Optional Light Kit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Control Bracket Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Changing Transmitter Frequency Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Remote Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TROUBLESHOOTING TIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CARE RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
AUTHORIZED SERVICE CENTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PRODUCT SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Owner's Manual
CONTENTS
C8U47M AT1206
H
ANOVER
1

Advertisement

Table of Contents
loading

Summary of Contents for Casablanca Hanover

  • Page 1: Table Of Contents

    READ AND SAVE THESE INSTRUCTIONS! Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this owner’s manual completely and carefully.
  • Page 2: Before You Start

    • Th is fan is designed to be installed on an existing electrical outlet box. Th e outlet box must be UL Listed for ceiling fan installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling installations.
  • Page 3: Mounting Recommendations

    ANOVER MOUNTING RECOMMENDATIONS GENERAL GUIDELINES Before mounting your Casablanca fan, read the following helpful recommendations. Th e location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mounting recommendations as you decide where to install your Casablanca fan.
  • Page 4: Fan Installation

    If you do not have an existing fi xture located where you wish After turning the power OFF at its source (either circuit to place your Casablanca fan, an approved ceiling fi xture breaker or fuse box), lower the old fi xture and disconnect outlet box must be installed and wired.
  • Page 5: Lag Screw Installation (Optional)

    Step 3. Attach the canopy to the crossbar mounting bracket with three of the 8-32 x 2 " long canopy screws (Pack B) and lock washers provided with your Casablanca fan. Tighten using the provided screwdriver until snug against the ceiling.
  • Page 6: Blade Installation

    BLADE INSTALLATION BLADE HARDWARE (not to scale) Pack C: Pack D: Blades (4) Blade Irons (4) Blade Screws and Washers (17) Blade Iron Screws (9) Attach Blade Irons Step 4. Using the screws in Pack C and the provided screwdriver, attach the blades to the blade holders by aligning the screwholes of the blade iron with the holes in the blade.
  • Page 7: Hanging The Fan

    ™ ANOVER FAN PREPARATION (CONT.) Ground Wire Motor Wires TIP: Th e downrod has a tapered thread that is designed (green) (leave at least 6" long) to lock completely when installed correctly. Perma•Lock™ Downrod Step 6c. Using the provided Allen wrench (attached to the and Ball Assembly paper motor warning shield), remove the Allen set screw Allen Wrench...
  • Page 8: Canopy Electrical Connections

    CANOPY ELECTRICAL CONNECTIONS Step 9. Attach the fan wires to the ceiling fi xture outlet box wiring by placing the bare ends of the wires side by side and Wire Nut then securing with a wire nut. Test that the connection is secure by pulling on the wire nut.
  • Page 9: Optional Light Kit Installation

    ™ ANOVER SWITCH HOUSING INSTALLATION (CONT.) Step 11d. Install the third screw and securely tighten all three screws by hand only using the provided screwdriver. Note: If you are not installing the optional light kit proceed to step 12. If you are installing the light kit, proceed to step Installing the No Light Cap Switch Housing No Light Cap...
  • Page 10: Versa•Touch2™ Control Installation

    VERSA•TOUCH2™ CONTROL INSTALLATION VERSA•TOUCH2™ HARDWARE (not to scale) Wood Screw Screw Drywall Anchor Screw 6-32 X " 6-32 X 1" 12v Battery 6-32 (2) 1" (2) W-73 W-73 Control Holder Control CONTROL BRACKET INSTALLATION SAFETY FIRST: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch. CAUTION! Do not use with wall dimmer.
  • Page 11: Changing Transmitter Frequency Setting

    ™ ANOVER REMOTE OPERATION Fan Control DOWNLIGHT To start the fan. Press the selected speed button to run the fan at the desired speed. Send Signal LOW=Low speed MED=Medium speed HIGH=High speed To turn off the fan, press the FAN OFF button. Airfl...
  • Page 12: Troubleshooting Tips

    TROUBLESHOOTING TIPS Please refer to this troubleshooting guide before requesting service or contacting your dealer for assistance. PROBLEM POSSIBLE REMEDIES Fan will not start • Check the main circuit fuses, circuit breakers, and wall switch position. Check all wire connections. Make sure the power is turned off during this inspection. •...
  • Page 13: Care Recommendations

    fi nish. No Need for Lubrication • Never lubricate this fan! Th e precision motor at the heart of your Casablanca fan features sealed bearings that are lubricated for life. • Do not attempt to oil the motor.
  • Page 14: Authorized Service Centers

    AUTHORIZED SERVICE CENTERS STATE/CITY SERVICE CENTER NAME PHONE TYPE STATE/CITY SERVICE CENTER NAME PHONE TYPE ALASKA COLORADO (Continued) Anchorage 99518 Bering Sea Eccotech 907-563-7988 Longmont 80501 Lumenarea.com, Inc. 303-485-6800 Loveland 80538 Fireside Lighting 970-669-3540 ALABAMA Mobile 36618 Azalea City Service Ctr. 251-341-0663 CONNECTICUT Tuscaloosa...
  • Page 15 ™ ANOVER STATE/CITY SERVICE CENTER NAME PHONE TYPE STATE/CITY SERVICE CENTER NAME PHONE TYPE IOWA MONTANA (Continued) Carroll 51401 J & L Electric Inc. 712-792-2444 Missoula 59801 Western Montana Lighting Supply 406-543-7166 Cedar Rapids 52404 Acme Electric Company 319-365-8677 NEBRASKA Coralville 52241 Ralston Creek...
  • Page 16: Product Specifications

    Fantasia Ceiling Fans 940-484-4222 St. Thomas, Virgin Islands 00805 Duane Loberg 304-775-2399 Denton 76201 Larry W. Goff 940-387-7304 PRODUCT SPECIFICATIONS Collection: Casablanca Designer Finishes: Crackled Walnut/Spanish Gold Model Name: Hanover Motor: 188 x 25mm Direct Drive Model Number: C8U47M Blade Span: 54"...