Rack-Mounting The Polycom SoundStructure Device

Warning
2 - 6
The Polycom SoundStructure can be mounted in an equipment rack, or placed
on a tabletop or other flat surface, or mounted under the table with the
optional undertable mounting kit.
Each SoundStructure device requires one rack space and does not require
additional empty rack spaces above or below the device.
When multiple devices are racked together, before final tightening of the rack mount
screws on each device after the first one, ensure there is enough clearance so that
the front-panel door will open freely.
To rack-mount the SoundStructure unit:
1. Remove the four front side screws and two mid-side screws on the
enclosure.
2. Align the rack ears, and install the rack ears using the screws that were
removed from the enclosure.
3. Mount the equipment in the rack and secure with the four supplied rack
mount screws (screw size is 10-32x1/2").
To place on a tabletop or other flat surface:
If the equipment will not be mounted in an equipment rack, it is recommended
that you install the four adhesive rubber feet on the bottom of the device (as
shown below) before placing the equipment on furniture.
TM
SoundStructure C16
SoundStructure C16
TM
TM
SoundStructure C16