PRODUCT DIMENSIONS

ZVC30
*Opening
The custom canopy must be sized to fit the insert
sleeve. Construct the canopy with an opening
that is:
26 W x 13-3/16 D
The opening must be constructed of 3/4 thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
1-1/4
7-1/2
4
Front side
The stainless steel liner is shipped with each hood
insert. This non-combustible liner protects the
underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may
construct a custom non-combustible liner. Use the
supplied liner as a template. The opening must be
26 W x 13-3/16 D. 3/4 thick material must
surround the opening to allow the sleeve locking
clips to engage. The insert sleeve inside the cabinet
should be positioned 1/2 from the rear wall so
that the center of the 8 duct is 5-1/2 from the
rear wall.
Design Information
28-1/2
1/2
21-1/4
5
Dimensions and Specifications (in inches)
Outside Dimensions
27-1/2
The Insert Sleeve
13
Front side
7/8
25-3/4
The bottom edge of the insert sleeve has a 7/8
wide flange on the sides and a 1/2 wide flange
on the front and back.
Remote Location for the Control
The control may be removed from the hood
and installed into a wall or countertop. A 30-ft.
length of wire is supplied to accommodate most
installations. A blanking plate covers the opening
when the controls are removed.
The overall size of the control is 4-1/4 wide and
2-1/4 deep.
1-11/16
Control cutout
We recommend that the cutout in granite or other
hard surfaces be made before the countertop is
installed.
14
16-3/4
14
13
1/2
3-11/16
1/2