DS7400XiV4-EXP | User Guide | 8.0 Personal Identification Numbers (PINs)
8.4

PIN Authority Levels

0 = Master
Can enter all commands, add or change PINs in assigned areas, change the time and date, bypass, arm, disarm,
perform system tests, system reset, and view history. User Number 001 must have the Master authority level. Any
or all PINs can behave as a Master code. The Master code always has authority in all partitions.
1 = Unlimited
Can enter all commands, bypass, arm, disarm, system reset, and perform system tests. It cannot change PINs.
2 = General
Can bypass, arm, and disarm. It cannot change PINs, system reset, enter [#][7], or any of the [#][8] functions.
3 = Arm Only
Can arm the system with [PIN][ON] arming sequence only. Cannot perform other functions, including disarming.
4 = Temporary
Valid only for a specified time (the PIN expires on a pre-determined date). It can arm and disarm the system, but
cannot perform any other functions. The code can be used from a Master keypad, but only in Single Partition
Mode. If access is assigned to more than one area, you must enter a Temporary PIN expiration date for all
assigned areas (refer to Section 8.5 Changing the Expiration Date for Temporary PINs).
5 = Duress
When the system is disarmed using the duress code, a silent report is sent to your monitoring service. The duress
code is intended to be used when the user is forced to disarm the system. Refer to Section 7.10 Turning OFF
(Disarming) Your System under Duress on page 22.
6 = Access Code
When a PIN with an access code is entered, any output programmed for access output (for example, door strikes)
pulse on for 10 seconds (works when the system is armed or disarmed).
8.5

Changing the Expiration Date for Temporary PINs

Since you can only change the expiration date for temporary PINs in Master Programming Mode, they are not
programmable from an RF (wireless) keypad. Do this procedure at a text keypad because no visual clues are
provided by an LED keypad.
Record your entries so they are available before you enter Master Programming Mode. Enter the
parameters promptly. If a delay of 15 seconds or more occurs between entries, the 3-beep error tone
sounds and the control panel exits from the programming mode.
Table 22: Changing the Expiration Date
Steps To Change the Expiration Date
Enter Master Programming Mode.
Enter 3 for Date of Code Expiration Setup
programming.
Enter the Expiration Month.
Enter the Expiration Day. The temporary PIN
expires at midnight on the day selected.
Enter the Year.
* Appears only when in Single Partition Mode.
Bosch Security Systems | 6/05 | 4998154961B
Command Sequence
[Master PIN][#][0]
[3]
[0][1] through [1][2]
January
December
[0][1] through [3][1]
Last two digits of the year
followed by [#]
Note: Enter the command sequence [Master Code][#][3][#] to cause the
text keypad to display the temporary code expiration date.
If Accepted, the Text Keypad Display Reads:
"3 Change Date of Code Expiration" *
(display scrolls to this)
"Enter Month"
(01 ... 12)
"Enter Day"
(01 ... 31)
"Enter Year"
(XX) End with #
"Month, Day, Year"
A long beep signifies acceptance.
EN | 24