Flexible control (Only works with Electrolux heat pumps)
Once ControlBox24/7 has been set up for the correct heat pump model, you can control your heat pump by sending text message to the unit.
Follow the instructions below for giving the command. Please note that this command will start the heat pump even when it is switched off.
The modes which can be selected on the heat pump are: HEAT, COOL and DRY.
To send a setting to the pump WITHOUT specifying a fan speed, enter the following:
<MODE><space><TEMPERATURE>
In the example above, the following setting is sent to the heat pump "Heat, 20°C, automatic fan speed"
An alternative to send to the heat pump is to state a specifi c fan speed by adding a colon after the temperature, and then entering the desired fan
speed. See the following:
<MODE><space><TEMPERATURE>:<FAN SPEED>
In the example above, the following setting is sent to the heat pump "Cool, 20°C, fan speed 2".
A list of the available settings for the various models is shown below.
*DRY = nonadjustable fan speed.
EHEAT
COOL
16-30
DRY
16-30 *
HEAT
8, 16-30
Fan speed
0 (auto), 1-5
Example: HEAT 20
Example: COOL 18:2
ECOOL
CHEAT
16-30
16-30 *
16-30 *
8, 16-30
8, 16-30
0 (auto), 1-5
0 (auto), 1-3
13

REMOTE CONTROL YOUR HEAT PUMP

TIP!
By sending the OFF command, you
can also switch off the heat pump.
CCOOL
HXHEAT
18-32
16-30 *
8, 16-30
0 (auto), 1-3
0 (auto), 1-3