Ignition Module / Ignition And Control Electrode / Sight Glass - Saunier Duval Thema CONDENS F 18 E SB Instructions For Use Installation And Servicing

Condensing boiler + instantanious hot water
Table of Contents

Advertisement

After fitting a new expansion vessel, fill
and purge the appliance or installation
if necessary.
15.4 Ignition module / Ignition and
control electrode / Sight glass
1
2
3
4
Legend
1
Ignition module
2
Ignition module harness connector
3
Ignition module retaining screw
4
Ignition and control electrode
connector
5
Ignition and control electrode
6
Ignition and control electrode retaining
screw
7
Circlip
8
Gasket
9
Sight glass
10
Gasket
11
Spring leaf
15.4.1
Ignition module
Remove the ignition and control
electrode connector (4) from the ignition
module (1).
Remove the ignition module harness
connector (2).
Remove the 2 ignition module (1)
retaining screws (3).
Fit the new ignition module by repeating
the operations in reverse.
11
10
5
9
6
7
8
15.4.2
Ignition and control electrode
Remove the ignition and control
electrode connector (4) from the ignition
module (1).
Remove the 2 ignition and control
electrode (5) retaining screws (6).
Fit the new ignition and control
electrode by repeating the operations in
reverse.
15.4.3
Sight glass
Remove the circlip (7).
Remove gaskets (8) and (10), the sight
glass (9) and the spring leaf (11).
Fit the new sight glass and the new
gaskets by repeating the operations in
reverse.