COD. 7
heating curve base
COD. 8
burner forcing
COD. 8 menus and following would only be used by After Sales Service Engineers.
COD. 23
select product code
set the offset on the
COD. 24
minimum fan speed
rmaximum
COD. 25
condensation power
Heating curve
90
80
70
60
25
50
40
30
20
2
Legend
1
Menu 6 setting
2
Menu 7 setting
Choose a value:
15°C / 16°C / 17°C / 18°C / 19°C / 20°C / 21°C / 22°C / 23°C
/ 24°C / 25°C
Select an operating mode:
0 - normal operation. (factory setting)
1 - forcing at P. mini.
2 - forcing at P. maxi.
Select a value between 0 and 199.
Select a value between 0 and 99 (99 = 990 rpm).
(no 10 rpm)
Select a value between 0 and 99 (99 = -1485 rpm)
(no 15 rpm)
4.0
3.5
15
3.0
2.5
2.0
Outdoor temperature (°C)
1
1.5
1.2
1.0
0.6
0.2