Legend
1
Automatic air vent
2
Pump retaining screw
3
Pump
4
Discharge pipe
5
Flow sensor retaining clip (*)
6
Flow sensor (*)
7
Flow sensor retaining clip (*)
8
Cold water filter retaining clip (*)
9
Cold water filter (*)
10
Filling tap (*)
11
Filling pipe retaining clip (*)
12
Filling pipe retaining clip (*)
13
Flow sensor connector (*)
14
"Foaming" filter retaining clip
15
"Foaming" filter
15.1.1
Pump
•
Unscrew the pump's 4 retaining screws
(2).
•
Remove the pump motor (3).
•
Fit the new pump motor by repeating
the operations in reverse.
15.1.2
DHW exchanger
•
Remove the two retaining screws (17)
accessible from the front of the boiler.
•
Remove the DHW exchanger (25).
•
Fit the new DHW exchanger by
repeating the operations in reverse.
•
Check the assembly direction: the word
"TOP" printed on the exchanger edge
(25) must be positioned towards the
top.
15.1.3
Flow sensor
•
Remove the retaining clip from the
filling pipe (12), and pivot the tap and
the filling pipe.
•
Disconnect the connector (13) located
under the flow sensor.
•
Remove the clips (5) and (7).
16
Discharge pipe retaining clip
17
DHW exchanger retaining screw (*)
18
Discharge valve
19
Heating safety valve
20
Heating safety valve retaining clip
21
Filling tap (*)
22
Heating pressure sensor retaining clip
23
Discharge retaining clip
24
Three-way valve
25
DHW exchanger (*)
26
Three-way valve connector
27
Heating pressure sensor connector
28
Heating pressure sensor
(*) Not required on SB models
•
Unscrew the cold water inlet joint under
the boiler.
•
Remove the flow sensor (6).
•
Fit the new flow sensor by repeating the
operations in reverse.
15.1.4
Heating pressure sensor
•
Remove the retaining clip (22) from the
heating pressure sensor.
•
Disconnect the connector (28).
•
Remove the heating pressure sensor
(29).
•
Fit the new heating pressure sensor by
repeating the operations in reverse.
15.1.5
Heating safety valve
•
Release the heating safety valve
retaining clip (20).
•
Remove the heating safety valve (19).
•
Fit the new heating safety valve by
repeating the operations in reverse.
15.1.6
Three-way valve
•
Disconnect the 3-way valve connector
(26).