Saunier Duval Thema CONDENS F 18 E SB Instructions For Use Installation And Servicing page 44

Condensing boiler + instantanious hot water
Table of Contents

Advertisement

Legend
1
Automatic air vent
2
Pump retaining screw
3
Pump
4
Discharge pipe
5
Flow sensor retaining clip (*)
6
Flow sensor (*)
7
Flow sensor retaining clip (*)
8
Cold water filter retaining clip (*)
9
Cold water filter (*)
10
Filling tap (*)
11
Filling pipe retaining clip (*)
12
Filling pipe retaining clip (*)
13
Flow sensor connector (*)
14
"Foaming" filter retaining clip
15
"Foaming" filter
15.1.1
Pump
Unscrew the pump's 4 retaining screws
(2).
Remove the pump motor (3).
Fit the new pump motor by repeating
the operations in reverse.
15.1.2
DHW exchanger
Remove the two retaining screws (17)
accessible from the front of the boiler.
Remove the DHW exchanger (25).
Fit the new DHW exchanger by
repeating the operations in reverse.
Check the assembly direction: the word
"TOP" printed on the exchanger edge
(25) must be positioned towards the
top.
15.1.3
Flow sensor
Remove the retaining clip from the
filling pipe (12), and pivot the tap and
the filling pipe.
Disconnect the connector (13) located
under the flow sensor.
Remove the clips (5) and (7).
16
Discharge pipe retaining clip
17
DHW exchanger retaining screw (*)
18
Discharge valve
19
Heating safety valve
20
Heating safety valve retaining clip
21
Filling tap (*)
22
Heating pressure sensor retaining clip
23
Discharge retaining clip
24
Three-way valve
25
DHW exchanger (*)
26
Three-way valve connector
27
Heating pressure sensor connector
28
Heating pressure sensor
(*) Not required on SB models
Unscrew the cold water inlet joint under
the boiler.
Remove the flow sensor (6).
Fit the new flow sensor by repeating the
operations in reverse.
15.1.4
Heating pressure sensor
Remove the retaining clip (22) from the
heating pressure sensor.
Disconnect the connector (28).
Remove the heating pressure sensor
(29).
Fit the new heating pressure sensor by
repeating the operations in reverse.
15.1.5
Heating safety valve
Release the heating safety valve
retaining clip (20).
Remove the heating safety valve (19).
Fit the new heating safety valve by
repeating the operations in reverse.
15.1.6
Three-way valve
Disconnect the 3-way valve connector
(26).