Saunier Duval Thema CONDENS F 18 E SB Instructions For Use Installation And Servicing page 24

Condensing boiler + instantanious hot water
Table of Contents

Advertisement

Position of the flue
Position
terminal
Horizontal flues
directly below an opening,
A
air brick,
opening windows
above an opening, air brick,
B
opening windows
horizontally to an opening,
C
air brick,
opening windows
D
below gutter, drain/soil pipe
E
below eaves
F
below a balcony or car port
from vertical drain pipes
G
and soil pipes
from internal/external
H
corners
to a boundary alongside
H*
the terminal
above adjacent ground or
I
balcony level
from surface or a boundary
J
facing the terminal
from opening (door/
L
window) in car port
into dwelling
M
vertical from a terminal
N
horizontally from a terminal
Vertical flues
P
from another terminal
Q
above roof level
from adjacent opening
R
window
S
from adjacent wall to flue
5.8.1 Horizontal concentric flue
mm
Ø 60/100
(C13 type installation)
300
300
300
1
25
25
25
25
25
Legend
300
1
Gasket
300
Maximum flue index: 150 Pa
This value is reached with the length of
600
the maximum duct (L) + 1 90° elbow.
1200
Flue model
Ø 60/100
1500
Every time a 90° elbow is used (or 2 off
300
45°), the length (L) should be reduced by
1 m.
600
300
A Plume management kit can be installed
at the extremity of the duct.
1000
Refer to the instructions sheet of the
300
accessory and take it into account the
following length:
Length L2 = L
0.5
1
2
3
4
Every time a 90° elbow is used (or 2 off
45°), the length (L1) should be reduced by
2 m.
L
7 2
Max. length
5.5 m
Length L1
8
7
5.5
3.5
2