6 Operating the boiler (user instructions)

6.1

Control panel

9
8
Legend
1
Operating indicator
2
Operating mode selection
3
Heating temperature adjustment
4
DHW temperature adjustment
5
Display of the temperature /
error codes
6.2

Commissioning and lighting

Make sure that:
-
the boiler is connected to the electrical
supply (the green indicator [1] blinks).
-
the gas service cock is open.
Turn the selector [2] bringing it in the
SUMMER
or WINTER
The operating indicator [1] on the
control panel turns on: the boiler is
ready to run.
Turn the selector [2] to modify the
operating mode of the boiler:
Central heating and
domestic hot water
Domestic hot water only
Installer mode
0
Stand-by and appliance
reset
frost protection
5
1 7
2
3
10
position.
4
6
Pressure gauge
7
Safety lockout indicator
8
Timeclock
9
Timeclock toggles
10
Timeclock mode selector
6.3

To program daily timeclock

Set the current time, by turning the dial [8]
clockwise until the current time is shown
against the indicator ' '.
Push in plastic toggles [9] against the time
you wish the heating to be off.
The timeclock can operate in three
positions: automatic '
permanently off '0', and heating
permanently on '1'.
To select, move the lever [10] to the
desired position.
NOTE: In case the electrical supply fails
the timeclock will not operate as
it has no back-up battery backup.
Therefore, it will be necessary
to reset the current time once
electrical supply is restored.
5
6
', heating

Hide quick links: