Model Specifications - Mitsubishi Electric FR-A500L Series Instruction Manual

Large capacity inverter fr-a560l-375k~900k-na
Table of Contents

Advertisement

6.1
Standard specification
6.1.1

Model specifications

Model FR-A560L-• • • K-NA
Applicable motor
(Note 1)
capacity (kW)
Rated capacity (HP)
(Note 2)
Rated current (A)
Overload capacity
Voltage
Rated input AC voltage, frequency
Tolerable AC voltage fluctuation
Tolerable frequency fluctuation
Power facility
capacity (kVA)
Protective structure (JEM 1030)
Ambient temperature
Cooling method
Approx. weight (kg (lb) )
Note: 1. The applicable motor capacity indicated is the maximum capacity applicable when Mitsubishi 4-pole
standard motor is used For A540K. (When National Electric Code based motor is used for A560L)
2. The rated output capacity indicated is based on National Electric Code for 460V for A540L. (575V for
A560L)
3. The overload capacity indicated in % is the ratio of the overload current to the inverter's rated current.
For repeated duty, allow time for the inverter and motor to return to or below the temperatures under
100% load.
4. The maximum output voltage cannot exceed the power supply voltage. The maximum output voltage
may be set as desired below the power supply voltage.
5. The power supply capacity changes with the values of the power supply side inverter impedance
(including those of the input reactor and cables).
6. For use in Variable torque mode, refer to Pr. 570.
7. For inverter environmental conditions (including ambient temperature) please check page A-3.
375
Constant torque
375
Variable torque
450
Constant torque
550
Variable torque
650
Constant torque
552
Variable torque
663
150% 60 sec., 200%
0.5 sec (inverse-time
Constant torque
characteristics)
120% 60 sec., 150%
Variable torque
0.5 sec (inverse-time
characteristics)
Constant torque
550
Variable torque
660
Open type (IP00)
-10 C to 40 C
(14 F to 104 F) at
VT
-10 C to 50 C
(14 F to 122 F) at
CT
490
(1078)
450
530
600
450
530
600
530
600
670
650
750
800
750
800
900
663
773
800
773
800
880
150% 60 sec. (inverse-time characteristics)
120% 60 sec. (inverse-time characteristics)
Three phase, 575V 50•^60Hz
Three phase, 575V 50•^60Hz
488 to 632V 50•^60Hz
660
770
797
770
797
896
-10 C to 40 C (14 F to 104 F)
Forced air cooling
500
1060
1060
(1100)
(2332)
(2332)
41
SPECIFICATIONS
670
750
670
750
750
800
900
1000
1100
1000
1100
1200
880
990
1100
990
1100
1210
•}5%
896
986
1095
986
1095
1205
Open type (IP20)
1100
1100
(2420)
(2420)
(2640)
800
900K
800
900
900
950
1200
1300
1210
1320
1205
1315
1200
1200
(2640)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a560l-375kFr-a560l-450kFr-a560l-900kFr-a560l-530k

Table of Contents