Parameter; Parameter List - Mitsubishi Electric FR-A500L Series Instruction Manual

Large capacity inverter fr-a560l-375k~900k-na
Table of Contents

Advertisement

4.1

Parameter List

PARAMETER

Func-
Parameter
tion
Number
0
Torque boost (Note 1)
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation frequency
11
DC injection brake operation time
12
DC injection brake voltage
13
Starting frequency
14
Load pattern selection (Note 1)
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High-speed maximum frequency
19
Base frequency voltage (Note 1)
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
*22
Stall prevention operation level
Stall prevention operation level at
*23
double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
28
Multi-speed input compensation
29
Acceleration/deceleration pattern
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost (Note 1)
47
Second V/F (base frequency) (Note 1)
Second
*48
current
Second
49
frequency
50
Second output frequency detection
Name
stall
prevention
operation
stall
prevention
operation
Minimum
Setting Range
Setting
Increments
0 to 30%
0 to 60Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 400Hz
0.01Hz
0 to 3600 sec/
0.1 sec/
0 to 360 sec
0.01 sec
0 to 3600 sec/
0.1 sec/
0 to 360 sec
0.01 sec
0 to 3600A
0 to 120Hz, 9999
0.01Hz
0 to 10 sec, 8888
0.1 sec
0 to 30%
0 to 60Hz
0.01Hz
0 to 5
0 to 400Hz
0.01Hz
0 to 3600 sec/
0.1 sec/
0 to 360 sec
0.01 sec
0,2
0 to 400Hz
0.01Hz
0 to 1000V, 8888, 9999
1 to 400Hz
0.01Hz
0,1
0 to 150%, 9999
0 to 150%, 9999
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0, 1
0, 1, 2, 3
0, 1, 2
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 400Hz, 9999
0.01Hz
0,1 to 9998
0 to 100%
0 to 400Hz
0.01Hz
0 to 400Hz, 9999
0.01Hz
0 to 3600 sec/
0.1 sec/
0 to 360 sec
0.01 sec
0 to 3600 sec/
0.1 sec/
0 to 360 sec, 9999
0.01 sec
0 to 30%, 9999
0 to 400Hz, 9999
0.01Hz
0 to 150%
0 to 400Hz, 9999
0.01Hz
0 to 400Hz
0.01Hz
18
PARAMETERS
Factory Setting
0.1%
1%
60Hz
0Hz
60Hz<50Hz>
60Hz
30Hz
10Hz
15 sec
15 sec
Rated output cur-
0.1A
rent
3Hz
0.5 sec
0.1%
1%
0.5Hz
1
0
5Hz
0.5 sec
1
0
60Hz
0.1V
9999<8888>
60Hz<50Hz>
1
0
0.1%
150%
0.1%
9999
9999
9999
9999
9999
1
0
1
0
1
0
9999
9999
9999
9999
9999
9999
1
0
0.1%
10%
6Hz
9999
5 sec
9999
0.1%
9999
9999
0.1%
150%
0
30Hz
Refer To
Page:
<Note9>
48
49
49
50
51
51
51
52
52
52
54
54
54
55
55
56
56
57
57
57
57
57
58
58
59
59
59
59
59
60
61
62
62
62
62
62
62
63
64
64
64
65
65
65
65
65
65
64

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a560l-375kFr-a560l-450kFr-a560l-900kFr-a560l-530k

Table of Contents