HP 220mx User Manual page 98

Optical jukebox
Hide thumbs Also See for 220mx:
Table of Contents

Advertisement

Operating This Jukebox on a SCSI Bus
The SCSI Bus and This Jukebox
It is very important that the 68-pin to 50-pin cable is properly configured to assure
that the eighteen truncated lines are properly terminated.
Cable Lengths
Observe SCSI cable maximum lengths;
- 3 meters (9.8 feet) for the single-ended bus (remember, this is a fast device)
- 25 meters (82 feet) for the differential bus.
Termination
Refer to the documentation that comes with your particular adapter to see how to
apply termination.
Use active terminators to reduce noise sensitivity.
Never terminate the bus at any place except the physical ends. Terminating the
bus in the middle will probably cause the bus to become inoperable or operate in
a state that could cause data loss.
If devices are on both sides of the host computer adapter (such as hard drives
internal to the host computer and a jukebox external to the host computer) make
sure that there is no termination on the host computer adapter. Termination must
be only on the device inside the computer that is farthest from the host adapter
and the physical device inside the computer, and the last physical device external
to the computer.
General
Do not connect a single-ended bus to a differential bus. Damage can occur.
B-10