Figure 22 Network diagram
Configuration procedure
# Configure IP addresses as shown in
Figure 22
and make sure the IRF fabric and PC can reach each
other. (Details not shown.)
# Examine the storage space on the member devices for insufficiency. If the free space is insufficient, use
the delete/unreserved file-url command to delete unused files. (Details not shown.)
# Log in to the FTP server at 10.1.1.1 using the username abc and password 123456.
<Sysname> ftp 10.1.1.1
Connected to 10.1.1.1 (10.1.1.1)
220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user
User (10.1.1.1:(none)): abc
331 Give me your password, please
Password:
230 Logged in successfully
Remote system type is MSDOS.
ftp>
# Set the file transfer mode to binary.
ftp> binary
200 TYPE is now 8-bit binary
# Download the file temp.bin from the PC to the Flash root directory of the master device.
ftp> get temp.bin
local: temp.bin remote: temp.bin
150 Connecting to port 47457
226 File successfully transferred
23951480 bytes received in 95.399 seconds (251.0 kbyte/s)
# Download the file temp.bin from the PC to the Flash root directory of the subordinate member (with
member ID of 2).
ftp> get temp.bin slot2#flash:/temp.bin
# Set the transfer mode to ASCII and upload the configuration file config.cfg from the IRF fabric to the PC
for backup.
ftp> ascii
200 TYPE is now ASCII
ftp> put config.cfg back-config.cfg
local: config.cfg remote: back-config.cfg
150 Connecting to port 47461