SETTINGS
>>> Output limitation in compressor mode
Factory setting
Lowest value
Highest value
Table 145 Output limitation
▶ Set the output permitted during compressor operation.
A low value can result in hot water peak failure.
>>> Output limitation when additional heat only
Factory setting
Lowest value
Highest value
Table 146 Output limitation
▶ Set the output permitted when the compressor is not in operation.
>>> Output limitation in hot water mode
Factory setting
Lowest value
Highest value
Table 147 Output limitation
▶ Set the output permitted during hot water production.
>> Regulator settings
>>> P constant
Factory setting
Lowest value
Highest value
Table 148 P constant
>>> I constant
Factory setting
Lowest value
Highest value
Table 149 I constant
>>> D constant
Factory setting
Lowest value
Highest value
Table 150 D constant
>>> Minimum PID signal
Factory setting
Lowest value
Highest value
Table 151 Minimum PID signal
>>> Maximum PID signal
Factory setting
Lowest value
Highest value
Table 152 Maximum PID signal
56
> Hot water electric heater
Under Additional heat, there are also settings for additional electric
6.0kW
heat in hot water heaters.
0.0kW
>> Acknowledge hot water additional heat
9.0kW
Factory setting
Alternative
Table 153 Additional electric heat, hot water
> Additional heat program
6.0kW
This function can be used to set the times between which additional heat
0.0kW
mode is blocked.
9.0kW
>> Activate program
Factory setting
Alternative
Table 154 Activate additional heat program
6.0kW
>> View/edit active program
0.0kW
Only displayed if a program has been selected.
9.0kW
>> Outdoor temperature limit for deactivation of time control
Only displayed if a program has been selected.
Factory setting
Lowest value
Highest value
4.0
Table 155 Outdoor temperature limit time control
0.1
▶ Set a suitable temperature for deactivation of time control. -26 °C =
30.0
If T2 is over set Outdoor temperature limit for deactivation of time
control for 15 minutes, or if Outdoor temperature limit for
deactivation of time control is set to Off, the additional heat will be
300.0
blocked by time control as long as Additional heat program is
activated.
5.0
If T2 is under set Outdoor temperature limit for deactivation of time
600.0
control or if Additional heat program is deactivated the additional heat
will not be blocked by time control.

20.9 SAFETY FUNCTIONS

0.0
• Setting collector circuit in T10
0.0
• Setting collector circuit out T11
10.0
The settings for collector circuit in/out are:
> Setting collector circuit in T10 /
Setting collector circuit out T11
>> Lowest permitted temperature E21.T10 / Lowest permitted
0%
temperature E21.T11
0%
Factory setting
100%
Lowest value
Highest value
Table 156 Lowest temperature, collector circuit
100%
0%
100%
Operating modes Mixed additional heat:
Extra hot water and Hot water peak requires additional
heat in the hot water heater
function Off.
No
Yes/No
No
No/Yes
-26 °C (Off)
-26 °C
20 °C
-6,0 °C (T10)
-8.0 °C (T11)
-10,0 °C
20,0 °C