Worcester Greenstar Oilfit Flexi CF Flue Installation Instructions Manual

Advertisement

Quick Links

Flue kit installation instructions
Floor standing oil condensing appliance flue
Greenstar Oilfit Flexi CF Flue
Conventional Flexible Flue Liner
0010028877-001

Advertisement

Table of Contents
loading

Summary of Contents for Worcester Greenstar Oilfit Flexi CF Flue

  • Page 1 Flue kit installation instructions Floor standing oil condensing appliance flue Greenstar Oilfit Flexi CF Flue Conventional Flexible Flue Liner 0010028877-001...
  • Page 2: Table Of Contents

    H Danger to life from poisoning by flue gas There is a danger to life from escaping flue gas. ▶ Ensure that flues and gaskets are not damaged. Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 3: Requirements

    ▶ Isolate all poles of the mains voltage and secure Conventional flexible flue liner against reconnection. For use with the following Worcester Greenstar oil-fired appliances: ▶ Make sure the mains voltage is disconnected. Utility 18/25, 32/50, 50/70 ▶ Observe the wiring diagrams of other system Danesmoor 18/25 components as well.
  • Page 4: Vertical Cf Kit Components

    ▶ Seals [7] must be located at the top and bottom of the flexible flue liner [8]. Refer to figures 16 and 18. 0010028880-001 Fig. 2 CF Flexible flue liner components (100mm) Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 5: Cf Stainless Steel Extension Components (100Mmø )

    100mmØ Inspection plate pack - Part number: 7 716 190 074 45° x 100mmØ Stainless steel elbow - Part number: 7 716 190 069 100mmØ Spare seal - Part number: 8 716 110 299 0 Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 6: Cf Flexible Flue Liner Kit Components (130Mmø )

    ▶ Seals [7] must be located at the top and bottom of the flexible flue be required if there are large irregularities on the chimney top face. liner [8]. Refer to figures 16 and 18. Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 7: Cf Stainless Steel Extension Components (130Mmø )

    130mmØ Inspection plate pack Part number 7 716 190 075 45° x 130mmØ Stainless steel elbow Part number: 7 716 190 073 130mmØ Spare seal - Part number: 8 716 110 155 0 Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 8: Pre-Installation

    Danesmoor (pre 2011) 18/25 Chimney cowl Heatslave 12/18 Flexible liner 18/25 Centralising spacer 25/32 Fire stop/Inspection plate Utility 18/25 Maximum two bends at 135° Stainless steel vertical section (minimum 600mm) 32/50 Boiler 50/70 Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 9 6720645523-46.1Wo Fig. 11 Damper fitting detail Fig. 9 Typical installation - straight flue Chimney cowl Flexible liner Centralising spacer Fire stop/Inspection plate Fire stop plate Stainless steel vertical section (minimum 600mm) Boiler Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 10: Installation

    7. Fit the stainless steel flue sections and clamp with the support brackets. Fig. 12 Prepare the chimney opening Flue adapter Flue section Support bracket 135° Flue bend Shorten this end only Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 11: Preparing The Flue Liner

    14 or if the bend is greater than 500mm follow the advice in figure 15 < 500 100mm Fig. 14 Installation in slightly angled chimney 130mm ≥ 500 Fig. 13 Preparing the liner Fig. 15 Installation in angled chimney Flexible flue liner Centralising spacer Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 12: Fitting The Seal And Lower Adaptor

    0010028924-001 Fig. 17 Chimney detail Stainless steel elbow Flue section Click 0010028888-001 Fig. 16 Adapter assembly Flexible flue liner Seal Grease Flue adaptor Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 13: Fitting The Support Bracket, Seal, And Adaptor

    Turn the cowl to reveal the marked securing points, drill and fit the Fig. 18 Terminal assembly wall plugs. Flexible flue liner Secure the cowl (7) with the screws provided. Chimney support bracket Silicon grease Seal Adaptor assembly Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 14 ▶ Cut the chimney cowl down along the moulded marks and use the inner set of securing points. Fit the grille (8) onto the terminal end and secure with the screw provided. 6720807910-18.1Wo Fig. 21 Finishing the installation Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 15 Installation Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05...
  • Page 16 CONTROLS AND CONNECTIVITY TEAM: 0330 123 3641 APPOINTMENTS: 0330 123 9339 SPARES: 0330 123 9779 LITERATURE: 0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Bosch Thermotechnology Ltd. Cotswold Way, Warndon Worcester WR4 9SW United Kingdom Tel. 0330 123 9559 worcester-bosch.co.uk...

Table of Contents