Hot Water - Worcester 6 KW Instruction Manual

Worcester greenstore lecp ground source heat pump in either system or combi variants
Hide thumbs Also See for 6 KW:
Table of Contents

Advertisement

SETTINGS

20.2 HOT WATER

Under Hot water, there are functions to:
• Acknowledge hot water sensor T3
• Extra hot water
• Hot water peak
• Hot water program
• Hot water mode
• Hot water settings heat pump x
• Block heating during hot water demand
• Maximum operating time for hot water at heating demand
• Hot water circulation
• Protective anode installed
> Acknowledge hot water sensor T3
Factory setting
Alternative
Table 79 Acknowledge hot water sensor
> Extra hot water
>> Extra hot water duration
Factory setting
Lowest value
Highest value
Table 80 Extra hot water duration
▶ Set the duration of extra hot water production.
>> Extra hot water stop temperature
Factory setting
Lowest value
Highest value
Table 81 Extra hot water stop temperature
▶ Set the stop temperature for extra hot water.
Additional amount of hot water is produced by temporarily increasing
the temperature of the hot water during the set number of hours to the
indicated stop temperature.
The heat pump starts the function directly and uses the compressor first
and then the additional heat source to increase the temperature. When
the desired number of hours have passed, the heat pump returns to
normal hot water mode.
DANGER: Risk of burn injuries.
▶ Use a mixing valve when the hot water temperature
exceeds 60 °C.
> Hot water peak
Hot water peak means a temporary increase in the hot water
temperature to approx. 65 °C for thermal elimination of bacteria
(pasteurisation).
The Hot water circulation pump is controlled by the control unit during
the hot water peak.
For the hot water temperature increase, the compressor is used first;
the additional heat source then continues alone.
>> Day of the week
Factory setting
Area
Table 82 Weekday
▶ Set the day on which the hot water peak should take place. None
means that the function is disabled. All means that a hot water peak
takes place every day.
If hot water peak is deactivated comfort mode must be selected in the
menu hot water mode.
48
Yes (if correctly installed)
Yes/No
0h
0h
48h
65 °C
50 °C
65 °C
Wednesday
None, Day, All
▶ Select None if electric additional heat in the hot water cylinder is
installed and controlled by external sources.
>> Interval in weeks
Factory setting
Lowest value
Highest value
Table 83 Week interval
▶ Set how often a hot water peak should take place.
– 1 means a hot water peak every week.
– 2 means that a hot water peak takes place in all even weeks of the
year, i.e. in week 2, 4, 6, etc.
– 3 means week 3, 6, 9, etc.
– 4 means week 4, 8, 12, etc.
>> Start time
Factory setting
Lowest value
Highest value
Table 84 Start time
▶ Set the time of the hot water peak.
>> Maximum time
Factory setting
Lowest value
Highest value
Table 85 Maximum time
>> Time for warm-keeping (Duration of hot water peak)
Factory setting
Lowest value
Highest value
Table 86 Time for warm-keeping
▶ Set Maximum time and Time for warm-keeping (Duration of hot
water peak).
The hot water peak is activated on the selected day and at the selected
time. It continues until the stop temperature has been reached plus
the time for warm-keeping (duration of hot water peak). The hot water
peak cannot continue longer than the set Maximum time. If it is
cancelled because the maximum time has expired, a message is
shown in the display and a new attempt is made after 24 hours.
> Hot water program
Program 1 and Program 2 enables you to block hot water production
during the set time.
>> Active program
Factory setting
Alternative
Table 87 Hot water program
>> View/edit active program
The menu is displayed only if Program 1 or Program 2 has been
selected. Programs are changed in the same way as for Room
temperature program (Chapter 20.1).
> Hot water mode
Factory setting
Alternative
Table 88 Hot water mode
1
1
4
3:00
0:00
23:00
3.0h
1.0h
5.0h
1.0h
1.0h
Maximum time - 1h
Always hot water
• Always hot water
• Program 1
• Program 2
Economy
Economy/Comfort
6 720 806 768 (2013/02)