Control Panel; Panel Overview; On/Off Button; Status Lamp - Worcester 6 KW Instruction Manual

Worcester greenstore lecp ground source heat pump in either system or combi variants
Hide thumbs Also See for 6 KW:
Table of Contents

Advertisement

15

CONTROL PANEL

Settings for the control of the heat pump are made with the control unit's
control panel, which also provides information about current status.

15.1 PANEL OVERVIEW

Fig. 42 The control panel
[1]

On/Off button

[2]

Mode button

[3]

Info button

[4]
Menu dial
[5]

Status lamp

[6]

Return button

[7]
Menu button
[8]

Menu display

15.2 ON/OFF BUTTON
Use the On/Off button to turn the heat pump on and off.
15.3 STATUS LAMP
The lamp lights continuously.
The lamp flashes rapidly.
The lamp flashes slowly, menu
window not lit.
The lamp and menu display not
lit.
Table 20 Lamp functions
1) Stand-by means that the heat pump is running but no heating or hot water
demand exists.
15.4 MENU DISPLAY
Use the menu display in order to:
• View information from the heat pump.
• View available menus.
• Change set values.

15.5 MENU BUTTON AND MENU DIAL

Use
to get from the Initial menu to the menus. Use the menu dial in
order to:
• Navigate the menus and get to the setting displays.
6 720 806 768 (2013/02)
The heat pump is running.
There is an alarm that has not been
acknowledged.
The alarm has been acknowledged
but the alarm cause remains.
The heat pump is in stand-by mode
No voltage to the control unit.
– Turn the dial to see more menus on the same level or change a set
value.
– Press the dial to change to a lower menu level or save a change.
15.6 RETURN BUTTON
Use
to:
• Go back to the previous menu level.
• Leave a setting display without changing the set value.
15.7 MODE BUTTON
Use
to change type of operation.
• Change type of operation.
The controller language can be changed with the
button.
▶ Press the
s, then select the required language.
15.8 INFO BUTTON
Use
to see information from the control unit about operating
mode, temperature, program version, etc.
16

START UP

The first time the heat pump is started, a number of settings are
displayed automatically so as to facilitate putting it in operation.
Before this stage, the heat pump should be installed in accordance with
the previous sections ( Chapter 13,
 Chapter 14). Collector circuits, heating circuits and hot water
circuits should be filled and vented.
The settings are also available under ordinary installer menus.
Only functions which are identified by the control unit
are displayed in the initial menu.
The start-up menus are available until Yes is entered in
Start-up completed.
▶ Read the complete menus before start-up.
▶ A selection must be made in Heat pump x capacity
and Protective anode installed.
LANGUAGE, COUNTRY, OPERATING MODE AND ELECTRICAL
CONNECTION
▶ Select language for the menus of the control unit
1)
.
( Chapter 20.10).
▶ Select Country ( Chapter 20.10).
▶ Select operating mode (L/W + electric additional heat)
( Chapter 8.4,  Chapter 20.7).
▶ Select Electrical connection (230V).
With the
once settings have been made.
START-UP
Review and adjust, as required, the functions below. See the references
for description of the functions.
The selected system solution would normally require a
review of more settings than the ones in the start-up.
CONTROL PANEL
button in the initial menu for at least 5
-button, return to the previous menu
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

7 kw9 kw11 kw7 kw9 kw11 kw

Table of Contents