Worcester 6 KW Instruction Manual page 66

Worcester greenstore lecp ground source heat pump in either system or combi variants
Hide thumbs Also See for 6 KW:
Table of Contents

Advertisement

FACTORY SETTINGS
Installer
General
Anti-seizure mode
Highest permitted flow temperature T1 Radiator/Underfloor
Operating mode
Groundwater
Display light switch off delay
Time for reset of access level
Heat pump x capacity
Connected I/O boards
Shows which circuit boards are
connected and their program version
Compressor working area
Outdoor stop function activated
Circulation pumps
Heating circuit pump G1
Heat carrier pump G2
Collector circuit pump G3
Screed drying
Activate
Heat source
Remaining time for current step
Program settings
Table 177 Factory settings Installer
Additional heat
Additional heat general
Start delay
Allow additional heat timer during energy supply cut-off
Additional heat only
Block additional heat
Maximum outdoor temperature for additional heat
Electric additional heat
Electric heater connection
Regulator settings
Mixed additional heat
Delay mixing valve control after additional heat start
Regulator settings
Hot water electric heater
Acknowledge hot water additional heat
Additional heat program
Active program
View/edit active program
Outdoor temperature limit for deactivation of time control
Table 178 Factory settings Additional heat
66
Day of the week
Start time
Groundwater
Compressor start delay groundwater
Operation alternative
Operation alternative
Pump speed E2x
> Fixed pump speed
> Temperature difference heat transfer fluid when heating
> Temperature difference heat transfer fluid when hot water
> Pump speed at no demand
Regulator settings
> P constant
> I constant
Operation alternative
Flow temperature increase per heating step
Number of days per heating step
Maximum flow temperature
Number of days with maximum temperature
Flow temperature decrease per cooling step
Number of days per cooling step
Connected output
Output limitation in compressor mode
Output limitation when additional heat only
Output limitation in hot water mode
P constant
I constant
D constant
Minimum PID signal
Maximum PID signal
P constant
I constant
D constant
Minimum PID signal
Maximum PID signal
Mixing valve running time
F value
Access level
Wednesday
1
12:00
1
80/45 °C
1
1
No
1
15s
1
5 min
1
20 min
1
(Start-up)
1
1
No
1
Continuous
1
Automatic
1
Auto
1
7K
1
7K
1
10%
1
3.0
1
300.0
1
Automatic
1
No
1
Additional heat
1
1
5,0K
1
1
1
45 °C
1
4
1
5,0K
1
1
1
F value
Access level
120 min
1
Economy
1
No
1
No
1
10 °C
1
9kW
1
6kW
1
6kW
1
6kW
1
4,0
1
300,0
1
0,0
1
0%
1
100%
1
20 min
1
2,0
1
300,0
1
0,0
1
0%
1
100%
1
300s
1
No
1
No
1
1
-26,0 °C
1
6 720 806 768 (2013/02)

Advertisement

Table of Contents
loading

This manual is also suitable for:

7 kw9 kw11 kw7 kw9 kw11 kw

Table of Contents