8

MESSAGES, WARNINGS AND FAILURES

INPUT 01
Fh= 15.6 kHz
Fv= 050 Hz
SOURCE 01
enter
password
x x x x
text on
text off
PROJECTOR
ADDRESS :
003
WARNING :
input not
available
WARNING :
source not
available
WARNING :
invalid
key entry
5975628 BARCOGRAPHICS 1209s 010797
When selecting a new source, in-
formation about this source will be
displayed on the screen. Source
number, horizontal and vertical fre-
quencies of the displayed source.
Announcement of the selected
source.
Message to enter your password.
Password contains 4 digits.
These messages will be displayed
on the screen when pushing the
TEXT key.
Text ON : the 'bar scale indication'
will be enabled during the change of
an analog control in the 'operational
mode' + all warnings and failures
will be displayed.
Text OFF : the 'bar scale indication'
will be disabled during the change
of an analog control in the 'opera-
tional mode' + all warnings and
failures will not be displayed.
Indication of the projector address
when activating the 'ADDRESS'
button on the RCU with a pencil or
other small object.
When using the projector with the
RCVDS, this warning will be dis-
played when selecting an input slot
of an RCVDS where the input board
is missing.
The input is a valid input but the
source is not connected to the
input terminals or the input source
is switched off.
When a wrong key is pressed on
the RCU.
Messages, warnings and failures
WARNING :
Message when the entered pass-
invalid
word is wrong.
code entry
WARNING :
End of adjustment range.
end of ad-
just range
WARNING :
Message will be displayed when
input no
the input source is no longer avail-
longer
able. The following message then
available
appears: 'check input signal or se-
lect new source'.
It warns you to check the power
WARNING :
connection or the power status of
input se-
the RCVDS.
lector not
Next message
available
immediatly on the screen : 'go to
stand-by'.
WARNING :
The entered frequency or applied
invalid
frequency of the source is out of the
frequency
projector's range.
input
Message to inform that selected
table is
table is deleted. This message will
be followed by 'confirm message',
deleted
on which the user has to answer.
FAILURE
Hardware failure. Call a qualified
service technician for repair.
I2C error
addr. : 7FH
FAILURE
Hardware failure. Call a qualified
short
service technician for repair.
circuit on
I2C bus
will appear
8-1