Technical Specifications - HP ProLiant BL465c Specification

Generation 8 server blade
Hide thumbs Also See for ProLiant BL465c:
Table of Contents

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Power Specifications
System Inlet Temperature Operating
Relative Humidity
(non-condensing)
Altitude
Acoustic Noise
DA - 14325 North America — Version 16 — December 13, 2013
HP ProLiant BL465c Generation8 (Gen8) Server Blade
7.11 x 2.18 x 20.37 in (18.07 x 5.54 x 51.76 cm)
Maximum: all processors,
16 DIMMs, hard drives,
mezzanine cards, and two
flash cache batteries
installed)
Minimum: one processor
and 2 DIMMs installed
For power specifications including input requirements, BTU rating, and power
supply output, please see the:
HP BladeSystem c3000 Enclosure QuickSpecs at
http://h18000.www1.hp.com/products/quickspecs/12790_na/
12790_na.html.
HP BladeSystem c7000 Enclosure QuickSpecs at
http://h18000.www1.hp.com/products/quickspecs/12810_na/
12810_na.html.
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at: www.hp.com/go/hppoweradvisor.
Non-operating
Operating
Non-operating
Operating
Non-operating
For acoustic noise specifications, please see the HP BladeSystem c-Class
14.00 lb (6.33 kg)
10.50 lb (4.75 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1,000 ft) above sea level to a maximum
of 3,050 m (10,000 ft), no direct sustained
sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The
upper limit may be limited by the type and
number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3,050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1,500 ft/min).
9,144 m (30,000 ft). Maximum allowable altitude
change rate is 457 m/min (1,500 ft/min).