Door springs and hardware.
Oil door rollers, bearings, and hinges.
-
Use silicone lubricant or light oil.
NOTE: Do not operate door automatically or manually if
springs are broken. CONTACT A PROFESSIONAL FOR
SERVICE.
Balance door.
Close door.
Release carriage from rail assembly.
-
Pull emergency release knob down.
Raise door manually about 3 feet.
-
Door should stay in that position.
NOTE: If door moves, HAVE DOOR SERVICED BY
A PROFESSIONAL.
Reattach carriage to rail assembly.
- Pull emergency release knob toward power head.
Close door
Contact reverse.
Lay 2" x 4" board flat on the floor in the center of
garage doorway (See page 28).
Close door using wall button or remote control.
NOTE: If door fails to reverse on contact with board. See
page 28, CONTACT REVERSE. If operator still fails,
replace operator or HAVE THE OPERATOR SERVICED BY
A PROFESSIONAL.
YEAR
Drive 8crew
Lubricate drive screw.
-
Use GENIE GLU3 lubricant.
Use only GENIE GLU3 lubricant, because other
lubricants may damage operator.
SOURCE (RED LED
0
ON
0
OFF
0
OFF
2 BLINKS, PAUSE (REPEAT)
2 BLINKS, PAUSE (REPEAT)
3 BLINKS, PAUSE (REPEAT)
INDICATED CONDITION
REQUIRED ACTION
SENSOR
(GREEN
LED
Q ON
0
OFF
0
ON
0
ON
0
OFF
ON
0
ON
NORMAL OPERATION
NONE REQUIRED
1 .POWER HEAD NOT POWERED
1 .CHECKBREAKERS,FUSES, PLUGS
2.WIRING FROM POWER HEAD BAD
2.CHECK WIRING FOR OBVIOUS SHORTS
1.WIRING TO SOURCE MISSING OR BAD
1.CHECKWIRING
2.POWER HAS BEEN INTERRUPTED
2.REMOVE POWERAND REAPPLY
1.BEAM NOT ALIGNED
2. BEAM OBSTRUCTED
1.CHECK ALIGNMENT
2. CHECKFOR OBSTRUCTION
3.SENSOR DEFECTIVE
3.CALL CUSTOMER SERVICE
1.WIRE TO SENSOR MISSING OR BAD
1.CHECKWIRING
2.SENSOR DEFECTIVE
2.CALL CUSTOMER SERVICE
1 .SENSOR RECEIVINGINTERFERENCE
1 .ATTEMPT TO DETERMINE SOURCEOF INTERFERENCE
2.CALL CUSTOMER SERVICE
1.SOURCE NOTSENDING PULSES
1.CALL CUSTOMER S ERVICE
4 BLINKS, P AUSE (REPEAT)
2.SOURCE D EFECTIVE
2.CALLCUSTOMER S ERVICE
NOTE: IF OPERATING
PROBLEM
EXISTS, THE DOOR CAN BE CLOSED
iF YOU:
I DISCONNECT
THE STB SYSTEM
FROM THE OPERATOR AND
2 HOLD WALL CONTROL
BUTTON
DOWN UNTIL DOOR IS CLOSED. (REMOTE
CONTROL
& WIRELESS
KEYPAD WILL NOT WORK WITHOUT
STB)
ii::
CUSTOMER
SERVICE:
1.800.354.3643
or
www.geniecompany.com