Other Convenience Commands - GarrettCom Magnum 3000 Installation And User Manual

Stackable hubs
Table of Contents

Advertisement

Magnum 3000 Stackable Hubs
After new subnet configuration information is set in operation, it will reside in
NVRAM. Powering down the Magnum 3000 will not destroy it, and at power up the
agent will read the configuration information from NVRAM and start operations with it.
5.4.3

Other Convenience Commands

From the top menu, one can also set the time and date. The time and date
do NOT reside in NVRAM and will be lost at power down. From the prompt, type:
T [ mm/dd/yy] [hh:mm] {Cr}
Example:
>T 11/12/93 11:45 {Cr}
To display the version and Ethernet physical address, from the prompt, type: V {Cr}
On the terminal, a message with version number and information about the processor,
system controller, Ethernet controller, and physical Ethernet address will appear in
response.
Example:
>V{Cr}
Garrett Communication Embedded Agent Version 01.01
Processor 3003 Controller 13
Ethernet Controller 30003003 Ethernet address 00 00 1A 18 0E 05
>
www GarrettCom com
.
.
Installation and User Guide (07/06)
sets the date and (military) time.