4 DIAGNOSTICS
Interactive Status
This diagnostic describes the interactive information that is displayed only when Thin
Client platform is running. The information on the OSD and front panel is updated at
least once every 5 seconds while the diagnostic is displayed. This is an example of a
code module display with status descriptions:
Figure 4-10 Interactive status front panel display
The Interactive Status fields are:
Field
IP Address
UPM
Upstream ID
Downstream
ID
State
Description
The IP address in dotted-decimal format xxx.xxx.xxx.xxx assigned by the NC 1500 to the
DCH6416. 0.0.0.0 is displayed if the IP address is not configured or unknown.
The upstream modem address value is the same as the terminal ID assigned by the
DAC 6000. It is a unique, system-generated, eight-digit integer between 1 and 16777215.
00000000 is displayed when the UPM is not configured or if it is unknown.
A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the DCH6416.
0000 is displayed if the Upstream ID is not configured or if it is unknown.
A four-digit decimal value from 0000 to 9999 assigned by the DAC 6000 to the DCH6416.
0000 is displayed if the Downstream ID is not configured or if it is unknown.
The interactive status of the DCH6416:
Front
OSD
panel
U
UNCONFIG
C
MAC_CONNECT
Description
The DCH6416 is not configured for the interactive system,
and the platform should run as pre-interactive.
The DCH6416 is waiting to establish connection to MAC PID
Stream.
61