Motorola DCH6416 Installation Manual page 72

Hide thumbs Also See for DCH6416:
Table of Contents

Advertisement

4 DIAGNOSTICS
Field
MAC Abort
Cntr
Socket Port
State
Description
I dc
INIT_WAIT_DC_O
R_C
I L
WAIT_LM_ACK
I SO
WAIT_SO_ACK
I LA
WAIT_LA_OR_SO
S I
INIT_STOPPED
r dc
RUN_WAIT_DC_
OR_C
r
RUNNING
S
RUN_STOPPED
00
INVALID
This counter increments every time the MAC layer reaches the cell abort count limit. It is
reset by the successful upstream transmission of a cell: for example, when the DCH6416
receives an ACK. If the counter reaches the MAC abort count limit, the DCH6416 assumes
the MAC layer is unavailable due to noise, congestion, or some other problem. The
DCH6416 stops transmitting data upstream, reports an error to the calling function, and
attempts to re-enter the network using the initialization process. 0000 is displayed as the
default or if the MAC Abort CNTR is not configured or unknown.
The socket mode and activity:
UNUSED—The socket is not being used.
OPENED—The socket is open.
READY—The socket is ready to send or receive.
RECEIVING—The socket is receiving data from the application server.
SENDING—The socket is sending data to the application server.
UNKNOWN—The socket state is invalid or unknown.
The DCH6416 is in the interactive initialization state and
waiting for the default configuration or the contention channel
list messages.
The DCH6416 is in the interactive initialization state and
waiting for Link Management Response ACK for Local
Address Message.
The DCH6416 is in the interactive initialization state and
waiting for a Sign On acknowledgement.
The DCH6416 is in the interactive initialization state and
waiting for Logical Address or Sign On with verification
Frequency message.
The DCH6416 is in the interactive initialization state and the
TransMode has stopped.
The DCH6416 is in the interactive state and waiting for the
default configuration or the contention channel list
messages.
Interactive state is running, sending idle messages, and
waiting for any prepare for poll or MAC messages.
The interactive run state has stopped and DCH6416 is
waiting for status or a transmission control message.
The interactive state is unknown or invalid.
62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dch6400 series