Disassembly Procedures
!

Touch pad

1. Disconnect power supply to unit.
2. Remove all four T-20H Torx screws securing control
panel facia.
3. Remove Control Panel.
4. Remove Control Board.
5. Remove two Pozi-drive screws securing touch pad to
Control panel.

Cycle Selector Switch

1. Disconnect power supply to unit.
2. Remove all four T-20H Torx screws securing control
panel facia.
3. Pull selector switch knob off switch shaft.
4. Remove two screws holding switch to control panel.
©2003 Maytag Appliances Company
WARNING
16022842 Rev. 0
To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.
5. Lay control panel forward.
6. Remove wires from switch (note switch position) and
remove switch.
Note:
When replacing switch, note the position of "top"
on the switch.

Transformer

1. Disconnect power supply to unit.
2. Remove Control Panel.
3. Remove two screws securing transformer and
disconnect wire harness.

Motor Run Relay

1. Disconnect power supply to unit.
2. Remove Control Panel.
3. Disconnect wires from Motor Relay.
4. Remove screw securing relay to Control Panel.
17