Temperature Settings; Advanced Settings And Diagnostics - Fetco CBS-2031e User Manual

Hide thumbs Also See for CBS-2031e:
Table of Contents

Advertisement

Temperature Settings

Parameter
Name
7
Water Temp. (qF)
8
Hot Water Service
9
Brew at Set
Temperature
Parameter
Name
10
Enter Advanced
Settings &
Diagnostics
Important! To save your changes, press

Advanced Settings and Diagnostics

Address
Description
50
Water Level
in Tank
52
Brew Basket
Sensor State
(left / right)
55
Tank Temperature
56
Brewer Model
Number
57
Reload Defaults
58
Temperature Scale
59
Water Volume
Scale
Range
Default Setting
180qF - 208qF
A (auto) / On / Off
0 - 1
Range
Default Setting
0 - 1
to exit programming mode and return to operating mode.
Range
Default
0 - 1
0 - 1
180qF - 208qF
31 - 52
0 - 1
0
F or C
F
LTR or GAL
LTR
10
Comment
Inside tank. Will be slightly lower at
200qF
spray head. To display in q Celsius,
see # 58 in Advanced Settings.
A (auto)
A= Faucet will dispense only when not
brewing.
On=Faucet always enabled.
Off=Faucet always disabled.
1
0=Will brew at any temperature.
1=Will brew only at set temperature.
Note: Changes will not take effect until
the next brew cycle is completed.
Comment
0
0 = Skip Advanced Settings &
Diagnostics. Loop back to start of
batch programming cycle.
1 = Enter Advanced Settings &
Diagnostics.
Press STOP to continue
Comment
Tests if water is touching probe.
0 = Tank is less than full
1 = Tank is full
CBS-2031s / CBS-2032s Only
To test, slide the brew basket in and out. Display
should toggle between 0 and 1.
0 = Brew basket out. 1 = Brew Basket in.
Displays current tank temperature. If temperature
is below 175qF, displays "LO".
Must be set for the correct model number of the
brewer: 31 for CBS-2031e or 2031s, 32 for CBS-
2032e or 2032s.
Changes all settings to default factory settings.
0 = Do not reload defaults
1 = Reload all default settings
If 1 is selected, you must advance to the next
address for this change to take effect.
Does not change address 56 – model number.
F = Displays temp in degrees Fahrenheit
C = Displays temp in degrees Celsius
LTR = Displays volume in liters
GAL = Displays volume in gallons

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbs-2032eCbs-2031sCbs-2032s

Table of Contents