Temperature Settings

Parameter
Name
7
Water Temp. (°F)
8
Hot Water Service
9
Brew Temperature
Protection.
Parameter
Name
10
Enter Advanced
Settings &
Diagnostics
Important! After programming, you must press and hold the HOT WATER button to save the settings and exit
programming mode, or changes will be lost.

Advanced Settings and Diagnostics

Address
Description
50
Water Resistance
(KΩ)
51
Water Level
Sensitivity
55
Tank Temperature
57
Reload Defaults
58
Temperature Scale
59
Water Volume
Scale
60
Brew Valve
Flow Rate
(oz or liters per
minute)
62
Bypass Valve
Flow Rate
(oz or liters per
minute)
Range
Default Setting
176°F - 204°F
Auto / On / Off
On / Off
Range
Default Setting
On / Off
Range
Default
0 - 200
LO - HI
LO
XXX°X
0 - 1
0
F or C
F
oz - LTR
oz
17 – 51
36
If #59 is oz.
0.50 – 1.50
1.05
If #59 is LTR.
17 – 51
44
If #59 is oz.
0.50 – 1.50
1.30
If #59 is LTR.
8
Comment
Inside tank. Will be slightly lower at
201°F
spray head. To display in ° Celsius,
see # 58 in Advanced Settings.
On
Auto= Faucet will dispense only when
not brewing.
On=Faucet always enabled.
Off=Faucet always disabled.
On
ON=Will brew only at set temperature.
OFF=Will brew at any temperature.
Note: Changes will not take effect until
the next brew cycle is completed.
Comment
Off
OFF = Skip Advanced Settings &
Diagnostics. Loop back to start of
batch programming cycle.
ON = Enter Advanced Settings &
Diagnostics.
Press STOP to continue
Comment
Displays the electrical resistance of the water in
kilohms as measured between the water level
probe and the tank. If greater than 200, or if the
tank is not full, the display will read – – – .
LO – 50 KΩ +/- 5KΩ
HI – 130 KΩ +/- 5KΩ
If water resistance (address 50) is greater than 25
KΩ, set on HI to prevent unwanted filling of tank.
Displays current tank temperature in °F or °C.
Changes all settings to default factory settings.
0 = Do not reload defaults
1 = Reload all default settings
If 1 is selected, you must advance to the next
address for this change to take effect.
F = Fahrenheit
C = Celsius
oz = Displays volume in ounces.
LTR = Displays volume in liters.
Use this to compensate for minor discrepancies in
actual volume versus programmed volume. Set
lower to increase volume, higher to decrease
volume.