Information Screens And User Settings - Fetco CBS-2121 ZURICH TS User Manual

Table of Contents

Advertisement

The CBS-2121-A displays the settings & operation conditions of the brewer.
This is a touch screen which allows the user to START or STOP a brew and adjust & change brewer settings.
Touching the carafe icon on the left side of the screen toggles batch size between "FULL BREW" (or Brew #1)
and "HALF BREW" (or Brew #2). (Screens 4 & 5 on the next pages describe how to configure both batch volumes)
Touching the two warmer icons on the left side of the screen toggles the carafe warmers ON/OFF.
MAIN ACCESS (Input Box on upper right side of screen)
FILLING: This brewer is manually filled before putting it into service. In AUTOMATIC mode, the hot water and tank fill
system will operate automatically when the tank level probe activates the fill valve based on liquid level.
HEATING-Two heating conditions are displayed:
"HEATING"-"START" is enabled when tank temp is within 1°C/2°F of the setpoint of the temperature sensor located in the
hot water tank (the "READY-START" box is displayed)
"HEATING"-Only (temp. <1°C/2°F of setpoint). No "READY-START" box indicates heater is ON and heating
BREWER SETTING INFORMATION (lower right side of screen)
TEMPERATURE UNITS: Hot water tank temperature is user adjustable UNITS (Fahrenheit or Celsius) are user selectable.
FILL MODE: Shows either AUTOMATIC or MANUAL (Pour Over) (water inlet valve disabled in MANUAL fill Mode).
Automatic-attached to water supply for self-fill and brew. Brew is timed and selectable for full or half batch.
ACCESSORIES (left side of the screen)
UPPER & LOWER WARMERS. Touch icon to turn warmer ON/OFF
FULL & HALF BATCH BREW: Touch icon to toggle from full to half batch brew volume in "AUTO" Mode
HOT WATER SERVICE BUTTON-Enabled in "AUTO" Mode only when "READY" displayed
Hot Water service will not operate during brew and is disabled when brewer is set in MANUAL Mode
EXAMPLES OF SCREENS FOR THIS
Filling
READY
START
92°C
TEMP.
MODE
Brewer is ON-set for FULL batch
Brewer is filling (in Automatic Mode)
Tank temperature low (<95°C)
WARMERS: Upper-OFF/Lower-ON
READY
START
95°C
TEMP.
MODE
Brewer is ON-set for HALF batch
Brewer in AUTOMATIC mode
READY START icon displayed
WARMERS: Upper-ON/Lower-ON

INFORMATION SCREENS AND USER SETTINGS

EQUIPMENT-For brewer information and to access brewer START/STOP
Automatic
Brewer is ON-set for FULL batch
Fill complete (in Automatic Mode)
Tank temperature low (<95°C)
WARMERS: Upper-ON/Lower-ON
Automatic
Brewer is ON-set for FULL batch
Brewer in MANUAL (Pour Over) mode
Brewer is READY for filling
Tank temperature at setpoint: 95°
WARMERS: Upper-OFF/Lower-OFF
Go to fetco.com for the latest versions of all information
HEATING
READY
START
92°C
TEMP.
MODE
Automatic
READY
START
95°C
TEMP.
MODE
Manual
Page 8
HEATING
91°C
TEMP.
MODE
Automatic
Brewer is ON-set for FULL batch
START icon disabled
Tank temperature low <95°C)
WARMERS: Upper-OFF/Lower-OFF
S
1:3013
TIME
2
Brewer completed FULL batch brew
Drip out time is preset to 1:30min.
In drip out mode: the outer frame is
flashing & the STOP icon is hidden
P169 NOVEMBER 2018

Advertisement

Table of Contents
loading

Table of Contents