To wire the Zone Controllers in parallel, a ZC-BOB must be used. Each Zone controller must
have a unique identification or number chosen using the DIP switches on the rear of the panel
(see diagram A). To wire in parallel, each controller must be wired into a port of the ZC-BOB
with a connecting wire going to the ZonePRO units (see diagram C).
The ID numbers on the left side of the window correspond to the identification number set
using the DIP switches on the individual zone controllers. To select ID#2 for example, simply
flip the 2 switch into the on position. ID 1-6 are connected to top ZC input on the rear panel
and ID 7-12 are connected to the bottom input. To create ID 7-12, add 6 to the ID # selected
on the back of the ZC. For example, to get an ID# of 10, connect to the bottom ZC Input (7-
12) and set the ID# to 4.

Zone Controller Installation

The installation of the Zone Controllers MUST be accomplished with the use of cable which is
rated VW-1 or higher. Common NEC designations which meet this rating include: CMP, CMR,
CMG, CM and CMX.
ZC-1 -
a wall panel.
ZC-2 -
f rom a wall panel.
ZC-3 -
ZC-4 -
safety applications applications.
ZC-Fire -
vates, the general purpose relay can typically be programmed to close if normally open or
vices-versa. The ZC-fire interface unit monitors the state of the relay (n.o. or n.c.) and upon
the state of change, notifies the ZonePRO, which then mutes its outputs.
ZC-6 -
es, it does not override the ZonePRO's implantation of scheduled scene changes. The poten-
tiometers used in ZC2 and ZC2 would override such a pre-scheduled scene change.
ZC-7 -
ZC-8 -
source/program select.
ZC-9 -
ZC-BOB -
ZonePRO™ User Manual
54
The ZC-1 is a programmable zone controller that allows volume level control from
The ZC-2 is a programmable zone controller that allows volume level and mute contro l
The ZC-3 allows wall panel program selection for the ZonePRO units.
The ZC-4 provides contact closure program selection for room combining or fire
The ZC-Fire is the interface to generic fire alarm relays. When fire alarm acti-
The ZC-6 is an up and down controller. Because the ZC-6 uses momentary switch-
The ZC-7 is used for momentary Mic Zone select.
The ZC-8 is used for a combination of volume up/down, and four position
The ZC-9 allows wall panel program selection for the ZonePRO 1260 and 1261 units.
The ZC-BOB allows parallel or home run cabling of the Zone Controllers.