A.4 - Link Input/Output
The link I/O connectors are used to pass program material from one box to another
instead of using "Y" cables to feed multiple 1260's. The link connectors are RJ45's. The Mic/Line
inputs and Source inputs 1-4 are fed to the Link Out. The program material coming out of the
Link Out has not been processed by the DSP. The input signal is routed to the LinkOut con-
nector. And the Link In is routed to the input circuitry. With the Link Out connected to anoth-
er 1260/1261 Link Input, both units are processing the same program material. Multiple units
can be daisy chained with the Link I/O for additional outputs from a single source.The Link I/O
of the RCA inputs are always active. The mic/line inputs have selection jumpers inside the unit.
These jumpers can be set to enable or disable Link In and or Link Out.
P12-CH1
P18-CH2
A.5 - Zone Controller Wiring and Install
Zone Controller Wiring
All Zone Controllers can be wired serially or in parallel. To wire in series, each Zone Controller
must have an identification number (ID) chosen using the DIP switches on the side of the con-
troller (see diagram A). Each controller must have a unique number chosen although there may
be multiple Zone Controllers controlling a single zone, or a single Zone Controller that controls
multiple outputs. The Zone Controllers can then be wired together and connected to the
ZonePRO units (see diagram B).