2075Q
2077Q
<Connecting the cords>
(4)
(1)
Work table hole
positions
(2)
(4)
(1)
(3)
(5)
(6)
(7)
(3)
(5)
(6)
(7)
(3)
(2)
(6)
(5)
(6)
(5)
4) Installation underneath the work table
* Standard BROTHER work tables are provided
with installation holes for use in installing the
transformer.
1. Remove the screws (1), and then remove the
handle (2).
2. Use the bolts (4), flat washers (5), spring washers
(6) and nuts (7) to install the transformer as
shown in the illustration, while leaving a gap of 2
mm between the work table and the cushion
collars (3).
Use the bolts (4), flat washers (5), spring washers
(6), nuts (7) and cushion brackets (3) which are
included.
2076Q
2 mm
2078Q
1. Loosen the screws (1), and then remove the
2079Q
transformer cover (2).
2. Connect the control box connector (3) to the
transformer connector (4).
3. Secure the connected cords with the cord holder
(5) and the screw (6), and place them inside the
transformer cover (2). Install the transformer
cover (2) with the screws (1).
4. Secure the cords to the work table using staples.
(1)
2080Q
HE-8000
4. INSTALLATION
19