NEC HV8600 User Manual page 133

Table of Contents

Advertisement

Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
0B59
Forced to use CPU#2 with
error
0B5A
Forced to use CPU#3 with
error
0B5B
Forced to use CPU#4 with
error
0B5C
Forced to use CPU#5 with
error
0B5D
Forced to use CPU#6 with
error
0B5E
Forced to use CPU#7 with
error
0B5B\F
Forced to use CPU#8 with
error
0B60
DIMM group #1 has been
disabled
0B61
DIMM group #2 has been
disabled
0B62
DIMM group #3 has been
disabled
0B63
DIMM group #4 has been
disabled
0B64
DIMM group #5 has been
disabled
0B65
DIMM group #6 has been
disabled
0B66
DIMM group #7 has been
disabled
0B67
DIMM group #8 has been
disabled
0B6F
DIMM group with error is
enabled
0B70
The error occurred during
temperature sensor reading
Explanation
An error was detected in CPU#2.
An error was detected in CPU#3.
An error was detected in CPU#4.
An error was detected in CPU#5.
An error was detected in CPU#6.
An error was detected in CPU#7.
An error was detected in CPU#8.
A memory error was detected in
memory DIMM group #1. Memory
DIMM group #1 is disabled.
A memory error was detected in
memory DIMM group #2. Memory
DIMM group #2 is disabled.
A memory error was detected in
memory DIMM group #3. Memory
DIMM group #3 is disabled.
A memory error was detected in
memory DIMM group #4. Memory
DIMM group #4 is disabled.
A memory error was detected in
memory DIMM group #5. Memory
DIMM group #5 is disabled.
A memory error was detected in
memory DIMM group #6. Memory
DIMM group #6 is disabled.
A memory error was detected in
memory DIMM group #7. Memory
DIMM group #7 is disabled.
A memory error was detected in
memory DIMM group #8. Memory
DIMM group #8 is disabled.
Memory error was detected.
An error was detected in the
middle of detection of abnormal
temperature.
Action
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Contact your service
representative.
Contact your service
representative.
Contact your service
representative.
Contact your service
representative.
Contact your service
representative.
Contact your service
representative.
Contact your service
representative.
Contact your service
representative.
The system is forcibly started
because errors are detected
in all memory devices.
Contact your service
representative.
Contact your service
representative.
Problem Solving 5-13

Advertisement

Table of Contents
loading

Table of Contents