NEC HV8600 User Manual page 131

Table of Contents

Advertisement

Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
0250
System battery is dead –
Replace and run SETUP
0251
System CMOS checksum
bad – Default configuration
used
0260
System timer error
0270
Real time clock error
0271
Check date and time setting
0280
Previous boot incomplete –
Default configuration used
02B0
Diskette drive A error
02B1
Diskette drive B error
02B2
Incorrect Drive A type – run
SETUP
02B3
Incorrect Drive B type – run
SETUP
02D0
System cache error – Cache
disabled
0B1B
PCI System Error on
Bus/Device/Function
0B1C
PCI Parity Error on
Bus/Device/Function
0B22
CPUs are installed out of
order
0B30
Fan 1 Alarm occurred.
0B31
Fan 2 Alarm occurred.
0B32
Fan 3 Alarm occurred.
Explanation
No system battery is installed.
Checksum of system CMOS is
not correct.
System timer error
Realtime lock error
Realtime clock is set incorrectly. Start the Setup Utility to set the
The previous activation has not
been terminated normally.
Error in floppy disk A
Error in floppy disk B
The type of drive A is incorrect.
The type of drive B is incorrect.
System cache error
A PCI system error occurred in
bus/device/function.
A PCI parity error occurred in
bus/device/function.
CPUs are installed in incorrect
order.
Memory cooling fan error
Memory cooling fan error
CPU cooling fan error
Action
Contact your service
representative to install the
battery. (After restarting the
computer, start the Setup Utility
to set required values again.)
The default values were set.
Start the Setup Utility to set
required values again.
Contact your service
representative.
Contact your service
representative.
time again. If the same error
occurs still, contact your service
representative.
If the system is started without
any modification, it is started in
the uncached status.
Correct the setup values by
using the Setup Utility and start
the system again.
Contact your service
representative.
Contact your service
representative.
Start the Setup Utility to set
required values again.
Start the Setup Utility to set
required values again.
No cache can be used. Contact
your service representative.
Contact your service
representative.
Contact your service
representative.
This does not indicate an error.
However, change the slot in
which the CPU is installed.
Check whether the fan is
clogged. Clean it if the fan is
covered with dust. If no error is
found or the failure is cleared in
spite of cleaning, contact your
service representative.
Same as above
Same as above
Problem Solving 5-11