Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
0B33
Fan 4 Alarm occurred.
0B34
Fan 5 Alarm occurred.
0B35
Fan 6 Alarm occurred.
0B36
Fan 7 Alarm occurred.
0B40
Invalid System Configuration Data System configuration data is
0B41
System Configuration Data Read
error
0B42
Resource Conflict
0B43
WARNING: IRQ not configured
0B44
Expansion ROM not initialized
0B45
System Configuration Data Write
Error
0B50
CPU#1 with error taken off line.
0B51
CPU#2 with error taken off line.
0B52
CPU#3 with error taken off line.
0B53
CPU#4 with error taken off line.
0B54
CPU#5 with error taken off line.
0B55
CPU#6 with error taken off line.
0B56
CPU#7 with error taken off line.
0B57
CPU#8 with error taken off line.
0B58
Forced to use CPU#1 with error
5-12 Problem Solving
Explanation
CPU cooling fan error
CPU cooling fan error
CPU cooling fan error
Optional board cooling fan error
damaged.
Read error on the data
configuring the system
The PCI board resource is not
properly mapped.
The PCI board interrupt is not
properly set.
The expansion ROM on the PCI
board is not initialized.
Write error on the data
configuring the system.
Because an error was detected
in CPU #1, it was disabled.
Because an error was detected
in CPU #2, it was disabled.
Because an error was detected
in CPU #3, it was disabled.
Because an error was detected
in CPU #4, it was disabled.
Because an error was detected
in CPU #5, it was disabled.
Because an error was detected
in CPU #6, it was disabled.
Because an error was detected
in CPU #7, it was disabled.
Because an error was detected
in CPU #8, it was disabled.
An error was detected in CPU#1. The system is started forcibly
Action
Same as above
Same as above
Same as above
Same as above
Start the Setup Utility to set
the time again. If the same
error reoccurs, contact your
service representative.
Ask your service
representative for System I/O
board replacement.
Start the Setup Utility for
reset. If the same error
reoccurs, contact your
service representative.
Same as above.
Check PCI board installation.
If the same error reoccurs,
ask your service
representative for System I/O
board replacement.
Ask your service
representative for System I/O
board replacement.
The CPU is disabled. Contact
your service representative.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
though an error is detected in
the CPU displayed. Contact
your service representative.