Production weighing unit
Table of Contents

Advertisement

Class
Item and Parameter
ap-p
Auto print polarity
ap-b
Auto print difference
data
Data memory
dout
int
Data output
Interval time
Not displayed
when BCD
output (OP-01)
is installed.
d-no
Data number output
5-td
Time/Date output
5-id
ID number output
pU5e
Data output pause
at-f
Auto feed
info
GLP output
ar-d
Zero after output
0
Plus only
1
Minus only
2
Both
0
10 digits
1
100 digits
2
1000 digits
0
Not used
1
Stores unit mass in counting mode
2
Stores weighing data
3
Stores calibration data
4
Stores upper/lower limit values
0
Every measurement
1
2 seconds
2
5 seconds
3
10 seconds
4
30 seconds
5
1 minute
6
2 minutes
7
5 minutes
8
10 minutes
0
No output
1
Output
0
No output
1
Time only
2
Date only
3
Time and date
0
No output
1
Output
0
No pause
1
Pause (1.6 seconds)
0
Not used
1
Used
0
No output
1
AD-8121 format
2
General data format
0
Not used
1
Used
Factory setting
Note: "Digit" is a unit of minimum weighing value
31
Description
Displayed value>Reference
Displayed value<Reference
Regardless of displayed value
Difference between reference
value and displayed value
Related items:
prt, int, d-no, 5-td, info
Interval time in the interval
memory mode when using prt 3,
data 2
Refer to "14. DATA MEMORY".
Selects whether or not the time
or date is added to the weighting
data. For details, refer to "10-9
Clock and Calendar Function".
Selects whether or not the ID
number is output.
Selects the data output interval.
Selects whether or not automatic
feed is performed.
Selects GLP output method.
For how to set time and date to
be added, refer to "10-9 Clock
and Calendar Function".
Adjusts zero automatically after
data is output.