Autostart AS-2510 TW Installation Manual page 7

Automatic transmission remote starter
Hide thumbs Also See for AS-2510 TW:
Table of Contents

Advertisement

(–) External
9
PURPLE
Trigger
(–) Ground
Out
10
WHITE
When
Running
11
GREY
(–) N/A
AS-2510 TW Installation Guide
The External Trigger wire can be used for remote-starting the
vehicle with an external device. When the vehicle is running,
triggering this input will activate Idle Mode. The External Trigger
wire can also be used to operate as a negative trigger with the
Trunk Pin-switch, the Key Sense wire or the Door Pin-switch:
Option 1 Connects to Negative Trunk Pin. When this wire is
programmed for
, pressing
TRUNK PIN
second
output. If ground (-) is detected on the
DISARM
(the Trunk has been opened), an
after the Trunk is closes. An
ARM
the
button is pressed if the Trunk pin state is unchanged
TRUNK
(The Trunk was unopened).
DISARM
previously locked and armed. If Secure Lock is enabled, UNLOCK
pulse(s) will be sent with
DISARM
pulse will be sent when the Trunk is closed or if the Trunk was left
closed.
Option 2 (Default: Engine Start/Stop): The first Ground (-) pulse on
this input will start the Engine, the second Ground (-) pulse on this
input will stop the Engine.
Option 3 (Key Sense (-) Input): Connects to OEM Key Sense Wire.
When the Key is detected in the Ignition Switch (Ground (-) signal
on the OEM Key Sense Wire) the Starter Kill will not
when it is set to Passive Mode. If Secure Lock is programmed,
and
will not be activated while the Key Sense input is
LOCK
ARM
active ("active" meaning there is a key in the Ignition barrel).
Option 4 (Smart Ignition Re-Lock): Connects to the Negative Door
trigger Input. When the Ignition Lock Option or the Lock Only
Option is enabled: after the Brake Pedal is pressed and after a
Door has been opened and closed, the Doors will
This wire provides a constant 500 mA ground output while the
Remote Car Starter is running. This output becomes active at the
same time as the Ignition and shuts off when the Remote Car
Starter shuts down, e.g.: when the Run Time has expired, when
the
button has been pressed, etc. This output can be used to
STOP
activate external relays, bypass kits, etc..
Caution! If multiple relays or modules are connected to the
wire, make sure they are diode isolated from one
OUT WHEN RUNNING
another: feedback may otherwise occur, causing damage to the
vehicle.
This pin is not used. Leave it empty.
will activate a 1-
TRUNK
PIN
TRUNK
pulse will be sent 5 seconds
ARM
pulse will be sent 4 seconds after
is sent only if the system was
, a
pulse and a
LOCK
REARM
even
ARM
.
RE-LOCK
GROUND
P. 7

Advertisement

Table of Contents
loading