Defect ID
Technical Severity
104988
105049
105098
105128
105174
IronWare Software Release 02.7.02a for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Summary of Software Fixes in R02.7.02a
Summary: Router continues to send LACPDUs in slow timer mode
after the far-end router reloads.
Probability: High
High
Feature: Link Aggregation
Function: LACP
Reported in Release: BigIron RX R02.7.02
Summary: The ipv6 ospf network point-to-multipoint command
can be configured on interfaces, but has no effect on OSPFv3 or the
running configuration.
Probability: Medium
High
Feature: IPv6 Routing
Function: OSPFv3
Reported in Release: BigIron RX R02.7.01b
Summary: A Management Module may reload if a router
configured with radius authentication is accessed through telnet
from an IPv6 Client.
Probability: High
High
Feature: Management
Function: Radius
Reported in Release: BigIron RX R02.7.02
Summary: After hot swapping a module, ARP broadcasts are not
forwarded out the module.
Probability: Medium
High
Feature: System
Function: ARP
Reported in Release: BigIron RX R02.7.02
Summary: A MSTP root-protected port remains in "designated-
discarding" stare after root protection times out.
Probability: Medium
High
Feature: MSTP
Function: Root protect
Reported in Release: BigIron RX R02.6.00e