Brocade Communications Systems PowerConnect B-RX Release Note page 42

Multi-service ironware software r02.7.02a for brocade bigiron rx series switches
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

Defect ID
Technical Severity
104389
104610
104691
104759
104986
IronWare Software Release 02.7.02a for Brocade BigIron RX Series Swtches
Release Notes v 1.0
Summary of Software Fixes in R02.7.02a
Summary: TCP initial sequence number generation does not fully
conform to RFC 793.
Probability: Medium
High
Feature: TCP Stack
Function: IP
Reported in Release: BigIron RX R02.7.02
Summary: Higher than normal CPU utilization on the management
interface when attempting to ping a non-existent host in the OSPF
network.
Probability: High
Medium
Feature: ARP
Function: IP Stack
Reported in Release: BigIron RX R02.7.02
Summary: Duplicate syslog messages and traps are generated
when configuring "snmp-server contact" or "snmp-server
location"
Probability: Medium
Medium
Feature: SNMP Management
Function: Syslog
Reported in Release: BigIron RX R02.7.02
Summary: No log entry or trap is generated when a standby
management module transitions from "standby (ready state)" to
"standby (down)"
Probability: Medium
Medium
Feature: System
Function: Syslog
Reported in Release: BigIron RX R02.6.00c
Summary: The show ipv6 route command give "C" as the type
code for directly connected routes in one part of the output and "D"
as the type code in another.
Probability: Medium
Low
Feature: IPv6 Routing
Function: CLI
Reported in Release: BigIron RX R02.6.00f