5. CAUTIONS AND RESTRICTIONS

5.1 Common Cautions and Restrictions for MegaRAID
Storage Systems(SAS/SATA)
Installing / uninstalling of MSM
MSM temporarily uses a dynamic port number (49152 or above) during installation.
MSM automatically releases the port at the end of installation.
If MSM is installed in a computer in which OS supporting Windows firewall such as
Windows XP is installed, the "Important warning on Windows security" window may
appear against "javaw" at the start of MSM. If this occurs, select [Remove block].
Windows Security Warning may be shown about "POPUP" when installing MSM. This
POPUP module is disabled in the installer of MSM, so there is no problem. The warning
message is no longer shown after system reboot.
The dialog of "warning of security" may be displayed during the process of
"Standby/Hibernation Lock" driver installation at MSM installation. In this case, select
"Yes" to continue the installation.
To control MSM by a remote computer, MSM must be installed in both local and remote
computers.
Popuplog.log file is created in C: drive at the time of MSM installation. This file is not
used after the reboot, so this file is able to remove after the reboot.
MSM operation
MSM client can not be started until MSM related service completes a start. When having
started a MSM client before starting service, the next error is indicated.
"Fatal Eror:Cannot connect to Framework!"
MSM related service is the following.
- Service Name: MegaMonitorSrv, Display Name: MRMonitor
- Service Name: MSMFramework, Display Name: MSMFramework
If you select [Replace Missing Physical Drive] in [Operations], a pull-down menu
without options appears in the right frame. Do not use the feature.
The firewall function which is provided by Windows OS disturbs the remote function of
MSM. Change the setting for the remote function of MSM. Review the port setting for the
firewall.
MSM uses port numbers 3071 and 5571. You cannot change these port numbers.
MSM uses any port numbers 32000 over temporarily.
Concurrent accesses by both MSMs in local and remote computers are possible.
However, only a single MSM can have the full access authority. If the full access authority
cannot be selected in the login mode, check whether an access from another client occurs.