NEC Express5800 series User Manual page 76

Megaraid storage manager
Hide thumbs Also See for Express5800 series:
Table of Contents

Advertisement

72 CAUTIONS AND RESTRICTIONS
166
Communication
enclosure:
168
Fan failed on enclosure:
170
Fan removed on enclosure:
171
Power
supply
enclosure:
177
Temperature
warning threshold on enclosure:
178
Temperature sensor below error
threshold on enclosure
Temperature
179
warning threshold on enclosure
Temperature sensor below error
180
threshold on enclosure:
Enclosure shutdown:
181
Too
many
182
connected to port. Enclosure
not supported:
Firmware
183
enclosure:
Sensor bad on enclosure:
184
Phy is bad on enclosure:
185
Unstable Enclosure:
186
Hardware error on enclosure:
187
No response from enclosure:
188
SAS/SATA
189
supported
disabled PD:
Unsupported
190
detected on SES enclosure:
BBU disabled; changing WB
195
logical drives to WT
Bad block table is 80% full on
196
PD:
Bad block table is full; unable to
197
log block:
Consistency
198
Due to Ownership Loss on VD:
Background Initialization (BGI)
199
aborted due to ownership loss
on VD:
Battery/charger
200
detected; SOH Bad
Single-bit ECC error; warning
201
threshold exceeded:
Single-bit ECC error; critical
202
threshold exceeded:
Single-bit ECC error; further
203
reporting disabled:
204
Power supply switched off for
enclosure:
206
Power supply cable removed on
enclosure:
211
BBU Retention test failed!
214
NVRAM Retention test failed!
lost
on
Check the connection of the enclosure.
Check the operation of the enclosure fan.
Check the connection of the enclosure fan.
failed
on
Check the power supply of the enclosure.
sensor
below
The temperature sensor exceeds over the
warning threshold. Check the temperature.
The temperature sensor exceeds over the
error threshold. Check the temperature.
sensor
above
The temperature sensor exceeds over the
warning threshold. Check the temperature.
The temperature sensor exceeds over the
error threshold. Check the temperature.
Check the enclosure.
enclosures
Decrease
enclosures.
mismatch
on
The compatibility with the firmware of the
enclosure is disabled. Contact the support
department.
Contact the support department.
The enclosure may be defected. Take the
replacement into account.
The enclosure may be defected. Take the
replacement into account.
The enclosure may be defected. Take the
replacement into account.
The enclosure may be defected. Take the
replacement into account.
mixing
not
SAS and SATA coexist in a specific
in
enclosure;
enclosure. Check whether the connection is
configured correctly.
hotplug
was
The hot-plug is not supported.
Check the battery.
The bad block table in the physical drive is
filled by 80% or larger. Replace the physical
drive.
The bad block table in the physical drive is
full. Replace the physical drive.
Check
Aborted
Check the authority.
Check the authority.
problems
Replace the battery.
Take the preventive replacement of the
physical drive into account.
Replace the physical drive.
Replace the physical drive.
Check the power of the enclosure.
Check whether the power cable of the
enclosure is disconnected.
Replace the BBU.
Replace the disk array controller.
the
number
of
connected

Advertisement

Table of Contents
loading

Table of Contents