38 Operation
[IO Policy]:
Select either Direct IO or Cached IO. The default setting is Direct IO.
[Access Policy]:
Select Read Write, Read Only, or Blocked. The default setting is Read Write.
[Disk Cache Policy]:
Select Unchanged, Enabled or Disabled. The default setting is Unchanged.
[Init State]:
Select the logical drive initialization procedure out of No Initialization, Fast
Initialization and Full Initialization. The default setting is No Initialization.
NOTE: Depending on the disk array controller you use,
some setting values may be restricted for stable system
performance and operation.
Refer to manuals coming with the Disk array controller and
server for the settings previously.
5. Check the contents of the array to be configured.
After checking the contents, click [Finish]. Then the logical drive is created.