NEC Express5800 series User Manual page 75

Megaraid storage manager
Hide thumbs Also See for Express5800 series:
Table of Contents

Advertisement

Rebuild failed due to target
102
drive error:
Rebuild started:
105
Rebuild automatically started:
106
Rebuild stopped due to loss of
107
cluster ownership:
Reassign write operation failed:
108
Unrecoverable medium error
109
during rebuild:
Unrecoverable medium error
111
during recovery:
SAS
topology
119
detected
SAS topology error: Device not
120
addressable
SAS topology error: Multiple
121
ports to the same SAS address
SAS topology error: Expander
122
error
SAS
topology
123
timeout
SAS topology error: Out of route
124
entries
SAS topology error: Index not
125
found
SAS
topology
126
function failed
SAS topology error: SMP CRC
127
error
SAS topology error: Multiple
128
subtractive
SAS topology error: Table to
129
table
SAS topology error: Multiple
130
paths
Unable to access device
131
134
Dedicated Hot Spare no longer
useful for all arrays:
137
Global Hot Spare does not
cover all arrays
140
VD Marked inconsistent due to
active writes at shutdown:
145
Battery temperature is high
146
Battery voltage low
148
Battery is discharging
150
Battery needs to be replaced,
SOH Bad
154
Battery relearn timed out
162
Current capacity of the battery
is below threshold
The target physical drive may be damaged.
Take the replacement of the physical drive
into account.
This
message
notification. The action is unnecessary.
This
message
notification. The action is unnecessary.
Check the authority.
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
error:
Loop
Check the connection of the disk array
controller.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
error:
SMP
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
error:
SMP
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Check whether the disk array controller is
connected correctly.
Take the preventive replacement of physical
drives into account.
Take the preventive replacement of physical
drives into account.
Check the consistency for confirmation.
The battery is heated at a high temperature.
If the error occurs frequently, take the battery
replacement into account.
If the error occurs frequently, take the battery
replacement into account.
If the error occurs frequently, take the battery
replacement into account.
Replace the battery.
Replace the battery.
If the error occurs frequently, take the battery
replacement into account.
CAUTIONS AND RESTRICTIONS 71
is
rebuilding
starting
is
rebuilding
starting

Advertisement

Table of Contents