NEC Express5800 series User Manual page 73

Megaraid storage manager
Hide thumbs Also See for Express5800 series:
Table of Contents

Advertisement

Alert report messages and actions against the messages
If MSM is installed, the following messages registered as "MSM" are set as report targets. To change
the setting, redefine it by the NEC ESMPRO Agent report setup procedure.
To change the setting, redefine it by the NEC ESMPRO Agent report setup procedure.
The event IDs in the table below are decimal numbers. Mark "√" in the Manager column indicates
the transmission of the report to NEC ESMPRO Manager. Mark "√" in the Alive column indicates
the transmission of the report to the express report service. Every report is sent as information.
Event
Message
ID
2
Unable to recover cache data
from TBBU
10
Controller cache discarded due
to memory/battery problems
11
Unable to recover cache data
due to configuration mismatch
13
Controller cache discarded due
to
firmware
incompatibility
15
Fatal firmware error:
17
Flash
downloaded
corrupt
20
Flash error
23
Flash programming error
24
Flash
timeout
programming
25
Flash chip type unknown
26
Flash command set unknown
27
Flash verify failure
32
Multi-bit ECC error:
33
Single-bit ECC error:
34
Not enough controller memory
46
Background
aborted on VD:
47
Background
corrected medium error:
Background
49
completed with uncorrectable
errors on VD:
Background
50
detected uncorrectable multiple
medium errors:
Background Initialization failed
51
on VD:
Consistency Check aborted on
56
VD:
Replace the disk array controller.
Check the memory and battery.
Replace the disk array controller.
Replace the disk array controller.
version
A firmware error occurs. Replace the disk
array controller.
image
The flash image may be damaged. Check
the flash image.
Replace the disk array controller.
Check the media used for flash. If the media
are not defected, replace the disk array
controller.
during
Check the media used for flash. If the media
are not defected, replace the disk array
controller.
Replace the disk array controller.
Replace the disk array controller.
Replace the disk array controller.
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
Take the replacement of the disk array
controller into account.
Initialization
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
Initialization
If the error occurs frequently, take the
preventive replacement of physical drives
into account.
Initialization
Take the preventive replacement of physical
drives into account.
Initialization
Take the preventive replacement of physical
drives into account.
Take the preventive replacement of physical
drives into account.
The consistency check is aborted. Check the
validity.
CAUTIONS AND RESTRICTIONS 69
Action
Mana
ALIVE
ger

Advertisement

Table of Contents
loading