Frymaster Y/KSCF/C/HC18G User Manual page 28

High efficiency cool zone series gas fryers
Table of Contents

Advertisement

Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
4.2 Start-Up Procedures (cont.)
B. Pilot lighting procedure – Electronic Ignition
a. Turn gas "ON."
b. Turn
controller/controller.
c. The ignition module will energize the pilot gas supply and the ignitor. The ignitor
spark will ignite the pilot gas. The presence of the pilot flame is then proven by a
flame sensor, which sends a signal to the main gas supply, opening the valve. The
operating thermostat or controller/controller controls the fryer after ignition.
In the event of prolonged power failure, the ignition module will shut down and lock
out the system. Turn the unit power "OFF" and then back "ON" after power has
d. If the pilot flame fails, the ignition module will shut down and lock out the system.
To restart, turn the electric power "OFF," wait approximately 5 minutes for the
system to recycle itself, and then turn the power "ON" again. Repeat Steps a-c.
3. KFC-1 Cooking Controller: Turn the controller ON and select cooking program as
described in the KFC-1 SMS Cooking Controller User Guide.
NOTE: For FAST-equipped fryers, see the Fast manual for operation instructions.
CHAPTER 4: DAILY OPERATION
electric
power
"ON"
been re-established.
ON/OFF Buttons
with
the
appropriate
WARNING
4-2
rocker
switch
or