Frymaster Y/KSCF/C/HC18G User Manual page 33

High efficiency cool zone series gas fryers
Table of Contents

Advertisement

Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS
Reinstall the hold-down ring. Ensure filter
9.
paper is properly aligned under the hold-down
ring. Press the filter paper into place with the
hold-down ring, ensuring the paper laps against
the walls of the filter pan.
Sprinkle 1 cup (8 ounces/227 grams) of filter
10.
powder evenly over the paper. Use a measuring
cup or scoop to evenly distribute filter powder
over the filter sheet.
Replace the crumb screen
11.
screen is cleaned throughout the workday.
Return pan cover to the filter pan.
12.
Return filter pan to fryer cabinet, ensuring that
13.
the two drainpipe extensions are directly over
the opening in the filter pan cover.
5.3 Filter Operations
NOTE: When left and right are indicated, refer to the operator's left and right.
Draining and filtering of cooking oil or shortening must be accomplished with care to
avoid a serious burn caused by careless handling. The oil to be filtered is at or near
350°F (177°C). Ensure all hoses are connected properly and drain handles are in
their proper position before operating any switches or valves. Wear all appropriate
safety equipment when draining and filtering oil.
CHAPTER 5: FILTRATION
Ensure crumb
.
DANGER
5-4